Laserfiche WebLink
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> CEILING <br /> # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type <br /> 1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood <br /> 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 N=>W Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0 <br /> 2 W=>S Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0 <br /> 3 S=>E Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0.6 0 <br /> 4 E=>N Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0 <br /> 5 N=>W Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0 <br /> 6 W=>S Garage Frame-Wood Main 11 16 0 8 8 138.7 ft2 0.23 0.01 0 <br /> 7 N=>W Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 <br /> 8 W=>S Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 <br /> 9 S=>E Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 <br /> 10 E=>N Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>W Insulated Main None .4 3 6 8 20 ft2 <br /> 2 N=>W Wood Main None .46 2 8 6 8 17.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). <br /> / Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 6 ft 0 in 0 ft 2 in None None <br /> 2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 6 ft 0 in Oft 1 in None None <br /> 3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 46.5 ft2 1 ft 0 in 10 ft 11 in None None <br /> 4 S=>E 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None <br /> 5 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 2 ft 0 in 0 ft 6 in None None <br /> 6 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 N 8.7 ft2 1 ft 0 in Oft-11 in None None <br /> 7 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 N 30.0 ft2 1 ft 0 in 2 ft 9 in None None <br /> 8 S=>E 9 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 1 ft 0 in Oft 11 in, None None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0 <br /> 8/26/2019 9:39 AM EnergyGauge@ USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 <br />