Laserfiche WebLink
MANDATORY REQUIREMENTS - (Continued) <br /> R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have <br /> heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a <br /> downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible <br /> to the storage tank. <br /> R403.5.6 Water heater efficiencies(Mandatory). <br /> R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable <br /> of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature <br /> setting range shall be from 100°F to 140°F(38°C to 60°C). <br /> Fi R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to <br /> electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of <br /> combustion types of service water-heating systems to be turned off. <br /> ❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of <br /> Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. <br /> Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate <br /> water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. <br /> R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy <br /> factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of <br /> Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, <br /> and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar <br /> water-heating systems should meet the following criteria: <br /> 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and <br /> 2. Be installed at an orientation within 45 degrees of true south. <br /> R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the <br /> Florida Building Code, Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation <br /> including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that <br /> close when the ventilation system is not operating. <br /> R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical <br /> ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. <br /> Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be <br /> powered by an electronically commutated motor. <br /> R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation <br /> shall meet the following criteria: <br /> 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable <br /> Indoor Air Quality,shall be the maximum rates allowed for residential applications. <br /> 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, <br /> crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. <br /> 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be <br /> insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 <br /> otherwise. <br /> R403.7 Heating and cooling equipment(Mandatory). <br /> R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the <br /> equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, <br /> based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and <br /> indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions <br /> described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that <br /> affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such <br /> as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency <br /> rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. <br /> TABLE R403.6.1 <br /> WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY <br /> FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU <br /> (CFM) (CFM/WATT) (CFM) <br /> Range hoods Any 2.8 cfm/watt Any <br /> In-line fan Any 2.8 cfm/watt Any <br /> Bathroom,utility room 10 1.4 cfm/watt <90 <br /> Bathroom,utility room 90 2.8 cfm/watt Any <br /> For SI:1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916 <br /> 8/26/2019 9:39 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 <br />