Envelope Leakage Test Report (Blower. Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: Permit#: <br /> Job I'nformatid'li <br /> Builder: DRH Express Homes Community: Lot: 26/7 <br /> Address: <br /> City: Zephyrhills State: FL Zip: <br /> Alr: L@akage Test<ReSUItS Passing results must meet either the Performance, Prescriptive; or ERl Method, <br /> O PRESCRIPTIVE METHOD=The building or dwelling:unit sfiall"be tested and verifie6as having-an air.leakage rate of:not exceeding:7 air <br /> changes per hour At,a pressure"of 0:2 inch w:g.(50 Pascals)in Climate Zones 1.arid 2:, <br /> :0. . PERFORMANCE"or.ERI METHOD-The."building'or dwelling unit shall be'-tested arid�Verified as having an air leakage'rate.of not,exceeding. <br /> the selected ACH(50)value;.as-shown on:Form R405=2017'(Pecforrriance)or R406-2017(ERI),.section labeled as.infiltration,,sub-section ACH50: <br /> ACH(50):specified on Form R405-2017 Energy Calc"(Performance)br-R406-2017(ERI): f 7.000 <br /> x 60 _ 22630 — Method for calculating building volume: <br /> CFM(50) Building Volume ACH(50) O Retrieved from architectural plans <br /> PASS •Code software calculated <br /> When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration <br /> control measures. <br /> 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br /> Testing Company <br /> Company Name: Phone: <br /> I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code <br /> Energy Conservation requirements according to the compliance method selected above. <br /> Signature of Tester: Date of Test: <br /> Printed Name of Tester: <br /> License/Certification#: Issuing Authority: <br /> 8/26/2019 9:39:50 AM EnergyGaugeO USA 6.0.03(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 <br />