My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21947
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21947
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 9:47:11 AM
Creation date
2/17/2021 9:47:09 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21947
Building Department - Name
DR HORTON INC
Address
7142 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro Summar Job: <br /> wrightsoftm Entire House Y Da <br /> By: <br /> Progressive Air Systems, Inc Plan: Hayden 2605 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Proeect Information <br /> For: DR Horton <br /> Lot 26 Blk 7 Silverado, Zephyrhills, FL <br /> Notes: <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 20622 Btuh Structure 22264 Btuh <br /> Ducts 6566 Btuh Ducts 8931 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower e) 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 27188. Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 31195 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2659 Btuh <br /> Ducts 1463 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2623 1 2623 Equipment latent load 4122 Btuh <br /> Volume (ft3) 21860 21860 <br /> Air changes/hour 0.22 0.11 Equipment total load 35317 Btuh <br /> Equiv.AVF(cfm) 80 40 Req. total capacity at 0.75 SHR 3.5 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042 Cond CH14NBO42 <br /> AHRI ref Coil FB4CNP042 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER <br /> Heating input Sensible cooling 30750 Btuh <br /> Heating output 38500 Btuh @ 470F Latent cooling 10250 Btuh <br /> Temperature rise 26 OF Total cooling 41000 Btuh <br /> Actual air flow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.050 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br /> Static pressure 0.56 in H2O Static pressure 0.56 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=31 OF <br /> Backup: <br /> Input=9 kW, Output= 29290 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> Wrl htsoft" 2019-Aug-26 09:40:05 <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.