My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22102
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22102
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 9:49:52 AM
Creation date
2/17/2021 9:49:51 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
19-22102
Building Department - Name
DR HORTON INC
Address
8023 SAIL CLOVER LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> 5 ' <br /> r <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.,shall be a minimum of 8"above the road elevation and an engineered sAe plan. <br /> 2. Lots shall be graded to comply with R401.3.'of the <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a k.O:W use permit., A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7. All.property markers shall be uncovered.and marked at time:of first inspection... <br /> .8:' All A.D.A. requirements shall be met: <br /> 9. No electric,plumbing; mechanical,or framing shall be covered without an inspection and <br /> approval first: <br /> 10: All Garages_shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location.where subject to mechanical.damage unless <br /> protected by approved barriers. M303;4 6f the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of-the F:B:C. <br /> 13. Foundation supports for A/C units shall be raised at least 3"-above finished grade. M1308:1 <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313-.1 of the F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308A.of the F.:B:C. <br /> 17. All means of egress are to be in accordance with R3I I of the F.B.C. <br /> 18. "Green.gypsum board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will:be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all. <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.