My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22116
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22116
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 10:52:10 AM
Creation date
2/17/2021 10:00:22 AM
Metadata
Fields
Template:
Building Department
Company Name
CVS 301 PROPERTY LLC
Building Department - Doc Type
Permit
Permit #
19-22116
Building Department - Name
CVS 301 PROPERTY LLC
Address
4718 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job name Just Stop Bargains <br /> Job# 0919C4S <br /> Sign company: Crazy 4 Signs <br /> Installation location: 4718 Gall Blvd.;Zephyrhills;•FL 33542 <br /> Section 1609.6.4 of Florida Building Code 2017 applies. <br /> Application of wind pressures using the alternative all heights method for components and cladding <br /> Type of structure: Inon illuminated panel sign 4mm ACM panel) <br /> Occupancy Category: II <br /> Ultimate design wind speed,figure C, FBC 2017, section 1609: 140 mph <br /> Wind stagnation pressure(qz)per 1609.6.3 FBC 2017 50.2 psf <br /> Net Pressure Coeficient(Cnet)from Table 1609.6.2(1) <br /> Components and cladding not in areas of discontinuity-walls and parapets -1.09 <br /> Wind Pressure -54.7 psf <br /> Wind load applied between wall and structure, pulling structure away from wall <br /> Load carried by tension in fasteners connecting structure to wall <br /> -maximum height of structure to be attached IA1.00 <br /> ft <br /> -maximum width of structure to be attached ft <br /> -fill factor <br /> -projected area of each component to be attached 20.0 ft^2 <br /> -wind load -1094 Ibs <br /> -design limit tension load per fastener to 150 Ibs <br /> -even number of fasteners minimum of 2= -8 <br /> -number of fasteners practically required due to structure shape 10 <br /> -weight of structure is approximately 100 Ibs <br /> -design limit shear load per fastener to 125 Ibs <br /> -average shear load per fastener= 10.0 Ibs <br /> Mounting surface construction is: 1cmu <br /> Use methods: 1l4"tapcons <br /> Method-1/4"x 1 1/4"Tapcon <br /> -depth of embedment in hollow concrete bock= 1 1/4" <br /> -pullout strength=754 Ibs <br /> -shear strength= 1218 Ibs <br /> httos://www.tapcon.com/getattachment/49dc7672-ddfd-4cf5-973d-eO5565349el0/charts performancetables bluewhitestainless v0-1 c.asax <br /> References: <br /> ASCE 7-10 <br /> The 6th Edition(2017)of the Florida Building Code <br /> s et: 2 of 2 <br /> S. <br /> .No 004.4089 <br /> ' STATE OF <br /> John J. Orlando PE LLC 0044089 <br /> 165 Old Ridge Road <br /> Macon, GA 31211 •Q <br /> (478)731-5394 ��I1VA i <br /> jjorlando@cox.net <br />
The URL can be used to link to this page
Your browser does not support the video tag.