Laserfiche WebLink
T <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 ME.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at leas_t 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 31. inch (1.9.1 mm)and larger in nominal_diameter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the water heater to a distribution manifold. <br /> Piping located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26. A copy of the enerry cacls shall be with yerns t at all times. <br /> 27. Copy of riHal insulation report shall be provided with permit before r1nab <br /> 28. No_fence, pool or screen-enclosure .is issued with.this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />