Laserfiche WebLink
ROCK- IT SY STef'1'1 4.0 <br /> SySTem sPeclFicaTions <br /> Max No.of Panels 300 Modules per ground lug Materials -300 Series Stainless, <br /> 6000 Series Aluminum <br /> Max System Voltage 100oVDC Coating BlackAndodiza4(on/Mili Finish <br /> Gass A Fire Rating With UL1703Type 1 Rated Lug Specifications Bumdy CL50-ITN Ground Lug <br /> Modules,see note below. (UL Listing#KDER E9999) <br /> Leveling.Range. 3-4" Ground Wire 14 AWG-4 AWG Copper <br /> Per above Lug spec. Ground Wire <br /> Rock-it Slide Comp Range 3' Max Module Size 64.96"(1650mm)x <br /> Rockat Slide Tile 7' 39.05'(992mm)is 2"(50mni) <br /> :Min/Max Roof Slope '1/2:12/12:12 Max Downforce/UpIllt Rating 45 PSF <br /> Max Anchor Spacing(35mm/40mm) 72' Rock-It Mount Load Rating 547lbs with Single 5/16'Lag 3:0 <br /> Max Anchor Spacing(32mm) 46" Safety Factor <br /> Skirt BOX.QTY 6 units Slide Fastening Hole 5/16"dlameter <br /> Mount Box QTY 12 units Module Cantilever Maximum cantilever is 1/3 <br /> Rock It Slide Box QTY 50 units bracket spacing <br /> Coupling Box M. 12 units Warranty 20Year Material and WoFkman- <br /> ship <br /> Codes:National-Electric Code;ANSI/NFPA 70,NEC 250,NEC 690,IRC,IBC <br /> Standards:UL 2703:First Edition,UL 1703 <br /> 'F,cOI'TS 5DIu ROCJhIT SYSTEM <br /> v�-;•:T'­.tv 'MPG ID CODE GGT-Q24016 <br /> unrmnnutto<• <br /> CONf0RM5T0UL 7/W CUNf0RM5T0 UC3703 <br /> lanunwvtnst.u.acti <br /> rya.. Ntu.u,ttrnwuutwos <br /> �!O .L�cn�um,vemcuoomn <br /> The EcoFasten Solar Rock-It System is a rooftop PV racking system consisting of 6000 Series Aluminum and 300 Series. <br /> Stainless.Steel components.The Rock-It System includes the rack components but does not include the PV panels, <br /> .Inverters or electrical-components.The PV modules to be used with Rock-It shall be certified under UL 1703.The <br /> system shall be used on steep slope roofs mounted over a Class Afire rated roofing material and attached'to the roof <br /> structure using:5/16".diameter,minimum 4"long 300 series Stainless Steel lag bolts with minimum thread <br /> embedment depth of 21/2"into the roof structure. <br /> Periodic re-inspection for loose components <br /> The system is subject.to re-inspection as required by the PV module manufacturer or.by the Authority.Having <br /> Jurisdiction:Re-inspectionVas required,should include evaluation of any loose components or loose fasteners.All <br /> .loose components and fasteners.should be secured.in accordance with these instructions.The system should also be <br /> .evaluated for any evidence of corrosion.Any corrosion should be removed.Any affected part should be cleaned or <br /> replaced in accordance with these instructions:. <br /> QrEcoFasten <br /> A Solar' - <br /> www.ecofastensolar com ihfo@ecofastensdiar.com 877-859-3947 15 <br />