My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22172
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22172
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 10:53:37 AM
Creation date
2/17/2021 10:45:32 AM
Metadata
Fields
Template:
Building Department
Company Name
ALPHA VILLAGE
Building Department - Doc Type
Permit
Permit #
19-22172
Building Department - Name
CARLEY,DAVID & ELAINE RUTH
Address
38550 CAMDEN AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:256E2782-CA2A-409B-95F8-A15D08B51768 <br /> Page 2 of 2 <br /> 3. The following mounting types shall be used. Please refer to the mounting details for the associated required <br /> penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per <br /> connection and therefore is adequate. <br /> • EcoFasten with Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications <br /> (NDS)of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. <br /> 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC <br /> 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. <br /> 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind <br /> load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount <br /> types indicated above. The following values have been verified by in-house testing and the mounting hardware <br /> manufacturers' data, which are available upon request. Panel support connections should be staggered, where <br /> possible,to distribute load to adjacent members. <br /> Modules in Landscape Modules in Portrait <br /> Roof Zone Interior Ede Corner Interior Ede Corner <br /> Max Vertical Spacing in 40 40 40 66 66 66 <br /> Max Horizontal Spacing in 48 48 48 48 48 48 <br /> Max Uplift Load Ibs 332 266 246 560 448 415 <br /> D.Summary <br /> Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will <br /> adequately support the additional loading imposed by the solar panels, if installed correctly.This evaluation has <br /> been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida <br /> Building Code-Residential 6th Edition, current industry standards and practice, and the information supplied to us <br /> at the time of this report. <br /> If there are any questions regarding the above, or if more information is required, please contact me. <br /> \�N\\\IIIII////,/ <br /> f t1E IIV W,q <br /> Regards, \�� ^.�- �,��E�►SF'•`S <br /> J. Matthew Walsh, PE * Nc�84 � <br /> FL License No. 84923 � .G — <br /> " STATE OF <br /> DocuS ed by: %�i� � P O ` P `Xv\� <br /> 7AEEB20514FE4D2... ONA <br /> 11/25/2019 <br /> Matthew Walsh <br /> November 26, 2019 1 8:55 AM MST <br /> This item has been electronically signed and sealed by <br /> Matt Walsh using a Digital signature and date. Printed <br /> copies of this document are not considered signed and <br /> sealed and the signature must be verified on any <br /> electronic copies. <br />
The URL can be used to link to this page
Your browser does not support the video tag.