R302.6 Dwelling-garage fire separation. <br /> The garage shall be separated as required by Table R302.6.Openings in garage walls shall comply with <br /> Section R302.5.Attachment of gypsum board shall comply with Table R702.3.5.The wall separation <br /> provisions of Table R302.6 shall not apply to garage walls that are perpendicular to the adjacent <br /> dwelling unit wall. <br /> TABLE R302.6 <br /> DWELLING-GARAGE SEPARATION <br /> SEPARATION <br /> MATERIAL <br /> From the residence and attics <br /> Not less than 1/2-inch gypsum board or equivalent applied to the garage side <br /> From habitable rooms above the garage <br /> Not less than 5/8-inch Type X gypsum board or equivalent <br /> Structure(s)supporting floor/ceiling assemblies used for separation required by this section <br /> Not less than 1/2-inch gypsum board or equivalent <br /> Garages located less than 3 feet from a dwelling unit on the same lot <br /> Not less than 1/2=inch gypsum board or equivalent applied to the interior side of exterior walls that are <br /> Within this area <br />