Laserfiche WebLink
Snow Load 21-30 psf <br /> Modules in Landscape <br /> -Wind S eed Exposure 2:12 c Roof Pitch<.6:12 7:12.<'Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone'2 Zone 3 . <br /> B 93 '59 <br /> 85 mph . . 110 mph C 67- 42 <br /> D 96 56 35 <br /> B 85 -54. <br /> 90 mph. 115.mph. C 104 61 38 <br /> D 68_ 51 32 <br /> B 72 46 <br /> 100 mph 125 mph . C 88 51 32 <br /> D 74 43 27 57 57 <br /> B 98 57 36 <br /> 110 mph 140 mph C 70 41 26' 66 54, 54 <br /> D 59 34 22 56' 46 46 <br /> B 85 50 - 31 66 66 <br /> 120 mph' ' 150 mph C 61 36 22 58 47 47 <br /> D 51 30 1 19 49 40 40. <br /> Notes: <br /> Spacing Governed by Snow Load <br /> 1.)Values in above-table represent the maximum allowable spacing In inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout rapacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6:)Based on Risk-Category II(ASCE 7-10)structures less than 30 feet in height,' <br /> 7.)Nl.adjustment factors are set to 1.No site specific engineering Is Included In this table <br /> Snow Load 21:-30. psf. <br /> Wind'S eed Exposure 2:12<Roof•Pitch<6:12 7:12_<Roof Pitch <br /> ASCE 7-05 ASCE 7-10 -Categoly Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> 33; <br /> 85 mph 110 mph C 12 <br /> D- 5 - <br /> B 49 30 <br /> 90 mph. 115 mph C 59 35 22 <br /> D 50 29 18 38 38 <br /> 100 mph 125 mph C 50 f 29 18-, 3.9 39 <br /> D 42 <br /> B 56. 33 20 <br /> 110 mph 140 mph C 40 23 14 38 31 3.1 <br /> D 34 19 12 32 26' 26 <br /> — B-- -- 49 - _ 2$- 18 --y6 `" 37 � " 37 <br /> " 27 27 <br /> 120 mph 150 mph C 35 20 12 33 <br /> D 29 17 10 28 2222« . <br /> Notes: <br /> -Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing In Inches for puilout.forces only on EcoFasten Solar standoff <br /> 2.)Maximum'allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed.standoff capcity=547#.(per,testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.):Values based on a.maximum module length of70" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1;No site specific engineering Is'Included in.this table <br /> www.ecofastensolarcom info@ecofastensoiarcom 877-859-3947 9 <br />