My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22078
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22078
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 11:45:17 AM
Creation date
2/17/2021 11:45:16 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR HEIGHTS
Building Department - Doc Type
Permit
Permit #
19-22078
Building Department - Name
WRIGHT,KARRI S TRUST
Address
39246 HEIGHTS AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUPPLY & MANUFACTURING <br /> J-DAN UcTAPRI110 t G6ilCoz� <br /> GULFED1 = TM <br /> 26 <br /> • • : . . .D <br /> FLORIDA PRODUCT APPROVAL NO. 11651.23 R3 <br /> TM <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. <br /> Product Description: GulfRibTM, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, <br /> through fastened roof panel over minimum 15/32" Plywood Decking. Non <br /> Structural application. <br /> Panel Material/Standards: Material: Minimum 26 Ga. Steel,ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code 2017 Section 1507.4.3. <br /> Paint Finish Optional <br /> Yield Strength: Min. 80.Oksi <br /> Corrosion Resistance: Panel Material shall comply with Florida Building <br /> Code 2017, Section 1507.4.3. <br /> Panel Dimension(s): Thickness: 0.018" Minimum <br /> Width: 36" Coverage <br /> Rib Height: 3/a" Major Rib at 9" O.C. <br /> Panel Fastener: #9-15 HWH 1.5" with sealing washing or approved equal <br /> 1/4" minimum penetration through plywood. <br /> Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 <br /> Substrate Description: Minimum 7-/3z" thick, APA Rated plywood over supports at maximum 24" O.C. <br /> Design of plywood and plywood supports are outside the scope of this <br /> evaluation. Must be designed in accordance w/Florida Building Code 2017. <br /> Design Uplift Pressures: Table"A" <br /> - - �_ :f:`i. <br /> IVlaximum.Total Uplift Design Pressure 71 75 psf <br /> Fastener Pattern 9"-9"-9"-91, 6.5"-2.5"-6.511- <br /> 2.5"6.5"-2.5"-6.5" <br /> Fasterer Pattern Spacing - 24 0 C 12 0 C . <br /> Design Pressure includes a Safety Factor=2.0. <br /> FL#11651.23 R3•OCTOBER 5,2017 <br /> • ® ® ® • . ® e <br /> ENGINEERING,KUITN <br />
The URL can be used to link to this page
Your browser does not support the video tag.