My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22093
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22093
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 11:09:24 AM
Creation date
2/17/2021 11:57:37 AM
Metadata
Fields
Template:
Building Department
Company Name
NESTLE WATERS NORTH AMERICA
Building Department - Doc Type
Permit
Permit #
19-22093
Building Department - Name
NESTLE WATERS NORTH AMERICA
Address
4330 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Membrane Type: SBS <br /> Deck Type 3I: Concrete Decks,Insulated: <br /> Deck Description: ; 2500 psi structural concrete or concrete plank <br /> System Type A(1): All layers of insulation adhered to deck with approved asphalt oradhesive. <br /> All General and System limitations apply. <br /> Base Insulation Layer(Optional) Insulation Fasteners Fastener <br /> Table 3 Density/ft2 <br /> One or more Iayers of any of the following insulations: <br /> Paratherm H;Multi-Max FA-3, H-Shield <br /> ]Minimum 1.5"thick N/A N/A <br /> Top Insulation Layer Insulation Fasteners Fastener <br /> Table 3 Density/ftz <br /> DensDeck - <br /> IV(inidi,,,:�1 %"thick N/A N/A <br /> DuraBoard <br /> Minlni➢l111 3/4"thick N/A N/A <br /> Note:: Co'nerete deck'shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to <br /> applieais•n of insulation. All insulation shall be adhered to the deck in full mopping of approved <br /> asphalt, within the EVT range and.at a rate of 20-40 lbs./100 ft' or Insta Stik Quik Set Insulation <br /> Adhesive!?hra-Stik Insulation Adhesive applied in continuous 3/4"to 1"wide beads at a maximum <br /> spacing of 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation <br /> attachment. Insulation listed as base layer only shall be used only as base layers with a second <br /> layer of approved top layer insulation installed as the final membrane substrate. Composite <br /> insulation 3anels used as a top layer shall be placed with the polyisocyanurate side facing down. <br /> Ply - Paradiene 20 TG,,20 HV TG,20 HT TG or 20 EG TG adhered by torch or <br /> Paradiene 20,20 HT,20 HV,20 EG adhered with approved mopping asphalt at an <br /> application rate of 20-40 lbs./sq.or with PA 31 1 or PA 31 I M adhesive at a rate of <br /> 1.5-2 gal/sq. <br /> Membrane: Paradiene 20 PR,30 FR,30 CR FR,30 MW FR or 30 HT FR adhered in approved <br /> mopping asphalt at an application rate of 20-40 lbs./sq. or PA 311 or PA 31 LM <br /> adhesive at a rate of 1.3-2 gal/sq.or Paradiene 20 PR T G,Paradiene 30 FR T C;30 <br /> CR FR TG or 30 HT FR TG adhered by torch: <br /> Note: Refer to manufacturer's specifications for specific application requirements. <br /> Surf'acina: Optional when granular surfaced membranes are used Required with non-granular <br /> surfaced membranes. Install one of the following: <br /> 1.400 lbs./sq.gravel in a flood coat of PA-311 or PA')11 M adhesive at an <br /> application rate of 3 gal./sq. <br /> 2.400 lbs./sq.gravel in a flood coat of asphalt applied at a rate of 60 ibs./sq. <br /> Maxhrit,m Design <br /> Pressure: -15 7.5 psf,,_using DensDecl:)(See General Limitation T9) <br /> 112.5 psf(using DuraBoard) (See General Limitation#9) <br /> NOA No.: 18-0620.04 <br /> Muu��E F�7Y Expiration Date: 04/14/23 <br /> Approval Date: 06/28/18 <br /> Page 8 of 36 <br />
The URL can be used to link to this page
Your browser does not support the video tag.