My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22093
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22093
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 11:09:24 AM
Creation date
2/17/2021 11:57:37 AM
Metadata
Fields
Template:
Building Department
Company Name
NESTLE WATERS NORTH AMERICA
Building Department - Doc Type
Permit
Permit #
19-22093
Building Department - Name
NESTLE WATERS NORTH AMERICA
Address
4330 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire Sprinkler Pipe <br /> Scheddle 10 and Schedule 40 <br /> Submittal <br /> FM.Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS <br /> Wheatland's Schedule 10 and Schedule 40 <br /> steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL <br /> C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES <br /> In. mm in. mm In, mm lbs./ft.,' kg/m 1 CRR' Lift <br /> Approvals and Specifications - <br /> Both products meet or exceed 1% 1.660 42.2 1.442" 36.6 .109 2.77 1.81 .2.69 7.3 61 <br /> ,the following standards:: '.l+h 1.900 48.3" 1.682. .42.7 J09 2.77 . 2.69 3.11 5.8 61 <br /> ASTM A135,Type E,Grade A(Schedule 10) <br /> 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93. 4.7 .37 <br /> .ASTM A795;Type E,Grade A(Schedule 40) <br /> 2% 2.875 73.0- 2.635 .66.9 .120. 3.05 3.53 5.26 3.5 30 <br /> NFPA 13 <br /> 3 3.500 68.9 3.260 . 82.8 J20 3.05 4.34 6.46 2.6 19 <br /> Manufacturing Protocols <br /> Schedule 10 and Schedule 40 are subjected 4 4.500 .114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 <br /> to the,toughest possible testing protocols to 5 5.563 141.3 5.295 134Z .134 3.40 7.78 .11.58 1.5. 13 <br /> ensure the highest quality and long-lasting <br /> .performance. 6 _ 6.625 168:3 6.357 161.5 .134 3.40 9.30 .13.85 1.0 10 - <br /> 8 8.625 219J 8.249. 209.5. .188 4.78 16.96 25.26 2.1 7 <br /> Finishes and Coatings" <br /> All Wheatland black"steel fire sprinkler pipe 'Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category MY.. <br /> •The CRR is a ratio value used to measure the ability of a pipe to withstand corioslom <br /> up to 6"-receives a proprietary mill Coating to Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). <br /> ensure a clean,corrosion-resistant surface that <br /> outperforms and outlasts standard lacquer <br /> coatings.This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS <br /> .easily painted,without special preparation. <br /> Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL <br /> black,'or with hot-dip.galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES <br /> FM/.ULrequirements for dry.systenls that meet in. mm In. ! mm In. mm lbs./ft kg/m CRR' Lift <br /> the zinc.coating specifications of ASTM A795" - ' - - -- <br /> or A53.All Wheatland galvanized material is 1 1.315. _ 33.4 1.049 26.6 .133 3.38 1.68, 2.50 1.00 70 <br /> also UL"Listed. - 1.660 '42.2 1.380 35J J40 3.56 2.27 :3.39 1.00 51 <br /> Product Marking 1"+4 1.900 48.3 1.610 40.9 .145 3.68 2.72. 4.05. 1.00 44 <br /> Each length of Wheatland fire sprinkler <br /> pipe IS continuously stenciled t0 show 2 2.375 .60.3 2.067 52.5 J54 3.91 3.66 .-5.45 1.00 30 , <br /> the manufacturer,type of pipe,grade,size 'Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. <br /> and:lengfFi.Barcoding is acceptable as a 'The CRR is a ratio value used to measure the abillty of a pipe to withstand corrosion. <br /> Threaded Schedule 40 steel pipe Is used as the benchmark(value of 1.0). <br /> supplementary identification method. O'' '' <br /> UL $. uL <br /> O APPROVED <br /> • : • • <br /> PROJECT: CONTRACTOR: DATE: <br /> ENGINEER:. SPECIFICATION REFERENCE: SYSTEM TYPE: <br /> LOCATIONS: COMMENTS: <br /> ❑ BLACK ❑ HOT-DIP GALVANIZED <br /> Wheatland Tube 00 South Dock StreetWht9atland Tube <br /> 00 •• 1 info@wheatland.com • • JMCSTEELGROUP - -" <br />
The URL can be used to link to this page
Your browser does not support the video tag.