Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe Withh-a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 31,inch (19.1 mm)and larger in nominal diameter, <br /> Piping serving more than:one dwelling unit. <br /> Piping located_outside the conditioned space:. <br /> Piping from the water heater to:a distribution manifold. <br /> Piping:located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O: <br /> 26. A cove of the-energy cacls-shall be with wermit at all limes <br /> 27. Coou of final insulation report shall-be or6vided with permit-before rnaL <br /> 28. No fence,pool or screen enclosure -is issued with:this permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />