Laserfiche WebLink
Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: 611600 Permit#: <br /> Job Information; <br /> Builder: A2&T16bmsfFmct16n Community: Lot: NA <br /> Address: Kennedy Avenue <br /> City: Zephyrhills State: FL Zip: <br /> Me LeakageJ''est Results Passing,results rnust meet either the Peiformance,-Prescdpti,ve,or ERI Method."' <br /> OPRESCRIPTIVE METHOD-The building or dwelling unit.shall be tested and verified as having an air=leakage rate of not exceeding l air. <br /> , changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2. <br /> ® PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and`verified as having an air leakage rate of-not exceeding <br /> the;selected ACH(50)value,as shoe n&on Form R405-2017(Performance)"or R406-2017(ER!),section labeled as infiltration,'sub-section.ACH50. <br /> ACH(50).specified on Form R405 2017-Energy Caic(Performande)or R406-2017(ERI):1 5.000 <br /> /J L� x 60 = 20106 = �� Method for calculating building volume: <br /> CFM(50) uilding Volume ACH(50) O Retrieved from architectural plans <br /> PASS • Code software calculated <br /> When ACH(50)is less than 3, Mechanical Ventilation installation O Field measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) <br /> Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section <br /> 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration <br /> control measures. <br /> 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems,if installed at the time of the test shall be turned off. <br /> 6.Supply and return registers,if installed at the time of the test shall be fully open. <br /> Testing,Company (�C <br /> Company Name: -v o . <br /> I hereby verify that the above Air Leakage results are in accord nce with the 2017 6th Edition Florida Buil ing Code <br /> Energy Conservation re ui i4g the compliance method selected above. <br /> Signature of Teste Date of Test: Z 2- <br /> Z� <br /> Printed Name of Tester: � . /L A/_ <br /> License/Certification#: � % �� Issuing Authority: EST, <br /> 51112019 8:51:58 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 <br />