Laserfiche WebLink
{ I <br /> Force Engineering&Testing Inc. <br /> 19530 Ramblewood Drive <br /> Humble,TX 77338 <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017,Sections 1709.2. <br /> Product Description: Ultra-Rib Wall Panel, 29 Ga. Steel, 36" Wide, through fastened structural wall <br /> panel. Structural Application. <br /> Panel Material/Standards: Material: 29 Ga.Steel,ASTM A792 or ASTM A653 G90 panel material shall <br /> comply with Florida Building Cade 2017 Section 1405.2. Optional Paint Finish. <br /> Yield Strength: Min.80.0 ksl <br /> Panel Dimension(s): Thickness: 0.0160"coated thickness(0.0142"uncoated thickness) <br /> Width: 36"maximum coverage <br /> Rib Height: Y:"major rib at 9"O.C. <br /> Panel Rollformer: MRS Metal Rollforming Systems <br /> Panel Fastener: #12-14 x V:" HWH SD with sealing washing or approved equal at 9"-9"-9"-9" <br /> fastener pattern. Panel side laps fastened together w/#12-14 x 3:"HWH SD with <br /> sealing washer at 24"O.C. <br /> Corrosion Resistance:Per Florida Building Code 2017. <br /> Substrate Description: Min.18 Ga.Grade 50 Steel Framing. Framing must be designed in accordance w/ <br /> Florida Building Code 2017. <br /> Allowable Design Pressures: <br /> Table"A" <br /> Maximum Design Pressure: -31.2 psf +26.0 psf <br /> Fastener Pattem: 9"-T-T-9" <br /> FastenerSpadng: 5'-0'O.C. 5'-0"O.C. <br /> 'Design Pressure includes a Safety Factor=2.0. <br /> ♦��%%t'C tir,r <br /> E <br /> o jyQ ♦, <br /> 4:1 OF <br /> 10 <br /> • Ho.Mi <br /> • "a" STATE OF a• : <br /> a <br /> O R I ..A, <br /> low M <br /> sum itO rii t1��,,, <br /> FL#9901.2 R3 <br /> August 16,z017 <br />