Laserfiche WebLink
Product Evaluation Report <br /> Rule 61G20-3 F.A.C. j Report into. 1951,Rev. 1 1 Project No. 05-0705 1 8/3/15*1 Page 1 of 3 <br /> Product Manufacturer Product home.Modelandior Desaiution <br /> Elixir Door and Metal Company Non-impact Glazed or Opaque,Inswing or Outswing,Painted Steel or <br /> 121S Pope Drive Vinyl Laminated Steel Doors with or without Strom Door—X <br /> Douglas,GA 31S33 <br /> Code:Current Edition of the Florida Building Code <br /> Caornolance Method:Fla.Admin.Code R.61G20-3.905(i)(a)—Certification Mark or Listing;as administered by the Florida <br /> Department of Business and Professional Regulation. <br /> Product Testing,Materials and Certification:Test Reports by Dallas Laboratories,Inc,1323 Wail ST.Dallas,TX MIS <br /> • ELIXOOS0.#44276,dated December 2:41011 to ASTM E330-02 <br /> • MOM-#44277,dated December 21,2011 to ASTM E330-02 <br /> • EUX0052:#44278,dated December 21,2011 to ASTM E330-02 <br /> • EID S3;044279,dated December 7-1,2011 to M M E330-02 <br /> Product installadDri instructions:All drawings fisted below by PTC Product Design Group,Revision A,Dated 8/3/1S,signed <br /> and sealed by Robert.J.Amoruso,P.E. <br /> • ELD OW.Model 402-14 Non-impact Outswing Vinyl Laminated Steel Door w/Storm Door <br /> • EUXOOS1:Model 402 20S Non-Impact Outswing Vinyl Laminated Steel Door w/Storm Door <br /> • EUX0052:Model407 Non-Impact Outswing Vinyl laminated Steel Door w/Storm Door <br /> • EUX0033:Model 430-W9 Non-Impact Outswing Vinyl Laminated Steel Door w/Storm Door <br /> Engineering Analysis&Evaluation:The following evaluations,engineering and/or rational analysis/calculations have been <br /> performed. <br /> • PTC PDG Report No.1933 Anchorage Engineering for doors shown on drawings EUXi0650,ELM0052,ELIX0052 and <br /> EUXi?0M3,signed and sealed by Robert).Amoruso,P.E. <br /> • PTC PDG Report No.1934,Anchorage Engineering for doors shown on drawings ELIX0036,signed and sealed by <br /> Robert J.Anioruso,P.E. <br /> • PTC PDG Report No.1935,Anchorage Engineering for doors shown on drawings.ELD(W33,EUX0037,ELIM39 and <br /> EUX0039,signed and sealed by Robert J.Amoruso,P.E. <br /> Limitations&Conditions of Use: <br /> • This product has NOT been evaluated for use Inside the HVHZ(High Velocity Hurricane Zone). <br /> • Refer to Product installation Instructions noted above for: <br /> o Maximum allowable wind loads at related maximum allowable size(s). <br /> o Maximum allowed sizes of fenestration components. <br /> a Anchor type(s),size(s),substrate(s),embedment,edge distance,and spacing/locations. <br /> • Site wind pressures shall be determined by a licensed professional engineer in accordance with the current edition <br /> of the Florida Building Code and/or ASCE 7:10 for components and cladding based on allowable stress design. <br /> • Site conditions not covered Iri this product evaluation document are subject to additional engineering analysis by a <br /> licensed professional engineer or registered architect as required by the authority having jurisdiction. <br /> • Adequacy ofthe existing structural substrates as a main wind force resisting system capable of-withstanding and <br /> transferring applied product loads to the foundation is the responsibility of the licensed professional engineer or <br /> registered architect acting as the design professional of record for the project of installation. <br /> MNUN A, PTC Product Design Group, L.LC i PO Box 520775 ( Longwood, FL 32752.0775 <br /> 321-690-1788 1 FBPE Certification of Authorization No. 25935 <br />