My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21935
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21935
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2021 11:25:25 AM
Creation date
3/24/2021 11:25:22 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-21935
Building Department - Name
HILTON JR,BOBBY E
Address
5885 13TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary Job: R0818410 <br /> Wrl htsoft� •y Date: 08/1012018 <br /> 9 Entire House By- MKC <br /> Bobby Hilton Construction, Inc. Plan: 611600 <br /> 39942 Offs Allen Rd,Zept"Ils,FL33540 Ptnre:(813)997-0515 <br /> Project • • <br /> For. Bobby Hilton Construction,Inc. <br /> Zephyrhills,FL 33540 <br /> Notes: Load calculation was obtained from a digital copy of the CAD drawing. <br /> Design Information <br /> Weather. Tampa Intl AP,FL,US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 27 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 grAb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 12742 Btuh Structure 13002 Btuh <br /> Ducts 3022 Btuh Duds 4413 Btuh <br /> Central vent(0 ctm) 0 Btuh Central vent(0 din) 0 Btuh <br /> none <br /> Humidlfic,ition 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipmentload 15763 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 17415 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2352 Btuh <br /> Duds 1307 Btuh <br /> Central vent(0 ctm) 0 Btuh <br /> Heatingg Coolingg (none) <br /> Area(ft) 1382 1382 Equipment latent load 3659 Btuh <br /> Volume(fP) 11056 11056 <br /> Airchanges/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 21074 Btuh <br /> Equiv.AVF(cfm) 83 42 Req.total capacity at 0.75 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Franklin or Eqv. Make Franklin or Eqv. <br /> Trade SplitHP Trade Split HP <br /> Model GSZ160241 Cond GSZ160241 <br /> AHRI ref 201667298 Coil ASPT291314 <br /> AHRI ref 201667298 <br /> Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER <br /> Heating input Sensible cooling 18000 Btuh <br /> Heating output 24000 Btuh @47-F Latent000ling 6000 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual airflow 800 ctm Actual airflow 800 cfrn <br /> Airflowfactor 0.051 cm/Btuh Airflowfactor 0.046 cfrnBtuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.83 <br /> Capacity balance point=33 OF <br /> Backup:Aux Heat <br /> Input=5 kW, Output=17061 Btuh,100 AFUE <br /> Calculations approved byACCAto meet all requirements of Manual J 8th Ed. <br /> wrightsoft` RigF w— tSu 2018-Arg-1411:45�8fe�Universal 201818.0.19 RSU20773 Page 1 <br /> ACACK..818410-Bobby FGltonCorshrfion\M818410np Calc=MJ8 FrordDoorfaces:E <br />
The URL can be used to link to this page
Your browser does not support the video tag.