Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department <br /> of Energy and Pacific Northwest National Laboratory. <br /> Adopted with permission <br /> Topic Section Component Description Yes N/A Exempt <br /> To be checked by Designer.or Engineer- <br /> Insulation C303.2 Envelope Below-grade wall insulation installed per . <br /> manufacturer's instructions. <br /> Insulation C303.2 Envelope Slab edge insulation installed per manufacturer's �{ <br /> instructions. r� <br /> Insulation C303.2 Envelope Above-grade wall insulation installed per <br /> manufacturer's instructions. <br /> Insulation C402.3 Envelope High-albedo roofs satisfy one of the following: <br /> 3-year-aged solar reflectance>=0.55 and thermal <br /> emittance>=0.75 or 3-year-aged solar <br /> reflectance index>=64.0. <br /> Fenestration C402.4.4 Envelope U-factor of opaque doors associated with the <br /> building thermal envelope meets requirements. <br /> SYSTEM—SPECIFIC C403.2.12.1 Mechanical HVAC fan systems at design conditions do not 11 <br /> exceed allowable fan system motor nameplate hp <br /> or fan system bhp. <br /> SYSTEM_SPECIFIC C403.2.12.2 Mechanical HVAC fan motors not oversized beyond allowable FM <br /> limits. Ell <br /> SYSTEM—SPECIFIC C403.2.3(8)Table Mechanical Heat Rejection Equipment:Minimum Efficiency �{ <br /> Requirement meet those listed in Table 7 't <br /> C403.2.3(8) <br /> HVAC C403.2.7 Mechanical Exhaust air energy recovery on systems meeting <br /> Table C403.2.7(1)and C403.2.7(2). <br /> SYSTEM—SPECIFIC C403.3 Mechanical Air economizers provided where required,meet <br /> the requirements for design capacity,control <br /> signal,ventilation controls,high-limit shut-off, <br /> integrated economizer control,and provide a <br /> means to relieve excess outside air during <br /> operation. <br /> SYSTEM—SPECIFIC C403.3.2 Mechanical Economizer operation will not increase heating 0 ❑ <br /> energy use during normal operation. <br /> SYSTEM—SPECIFIC C403.3.4, Mechanical Water economizers provided where required, ❑ <br /> C403.3.4.1, meet the requirements for design capacity, <br /> C403.3.4.2, maximum pressure drop and integrated <br /> C403.3.1 economizer control. <br /> SYSTEM—SPECIFIC C403.4.2.1 Mechanical Three-pipe hydronic systems using a common 0 ❑ <br /> return for hot and chilled water are not used. <br /> SYSTEM—SPECIFIC C403.4.2.3.1 Mechanical Hydronic heat pump systems connected to a 11911 <br /> common water loop meet heat rejection and heat <br /> addition requirements. <br /> SYSTEM—SPECIFIC C403.4.3.4 Mechanical Open-circuit cooling towers having water cooled <br /> chiller systems and multiple or vairable speed <br /> condenser pumps,are designed so that tower <br /> cells can run in parallel with larger of flow crtieria. <br /> SYSTEM—SPECIFIC C404.2 Mechanical Service water heating equipment meets efficiency <br /> requirements. <br /> Wattage C405.3 Interior Lighting Exit signs do not exceed 5 watts per face. <br /> -2.To,be checked by Plan"Reviewerµ' <br /> Plan Review C103.2 Envelope Plans and/or specifications provide all information <br /> with which compliance can be determined for the <br /> building envelope and document where <br /> exceptions to the standard are claimed. <br /> EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option <br /> 9/4/2019 Page 9 of 15 <br />