ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
19-21985
Building Department - Name
SF ZEPHYR COMMONS OUTPARCELS LP
Address
38011 PRETTY POND RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pressure Location Make and Setting Static pressure Residual pressure Flow rate <br /> reducing and floor model• (flowing) <br /> valve test Inlet(psi) Outlet(psi) Inlet(psi) Outlet(psi) Flow(gpm) <br /> Hydrostatic:Hydrostatic test shall be made at not less than 200 psi(13.6 bar)for 2 hours or 50 psi(3.4 bar) <br /> above static pressure in excess of 150 psi(10.2 bar)for 2 hours.Differential dry-pipe valve clappers shall be left <br /> open during the test to prevent damage.All aboveground piping leakage shall be stopped. <br /> Test <br /> description Pneumatic:Establish 40 psi(2.7 bar)air pressure and measure drop,which shall not exceed 1 1/2 psi(0.1 bar) <br /> in 24 hours.Test pressure tanks at normal water level and air pressure and measure air pressure drop,which shall <br /> not exceed 1 1/2 psi(0.1 bar)in 24 hours. <br /> All piping hydrostatically tested at 200 psi ( bar) for 2 hours If no,state reason <br /> Dry piping pneumatically tested =Yes �Ne <br /> Equipment operates properly =Yes =NO <br /> Do you certify as the sprinkler contractor thal additives and corrosive chemicals,sodium silicate or derivatives <br /> of sodium silicate,brine,or other corrosive chemicals were not used for testing systems or stopping leaks? <br /> Yes =No <br /> Test Drain Reading of gauge located near water Residual pressure with valve in test <br /> test supply test connection psi ( bar) connection open wide psi ( bar) <br /> Underground mains and lead in connections to system risers flushed before connection made <br /> to sprinkler piping Other Explain <br /> Verified by copy of the U Form No.85B F7X Yes =No <br /> flushed by installer of underground <br /> sprinkler piping =Yes =No <br /> If power driven fasteners are used in concrete,has =Yes =No If no,explain <br /> representative sample testing be satisfactorily, <br /> completed? N/A <br /> Blank testing Number used Locations N/A Number removed <br /> gaskets <br /> Welding piping =Yes =No <br /> If yes... <br /> Do you certify as the sprinkler contractor that welding procedures comply F x ]Yes No, <br /> with the requirements of at least AWS B2.1? <br /> Welding Do you certify that the welding was preformed by welders qualified.in XYes =No <br /> compliance with the requirements of at least AWS B2.1? <br /> Do you certify that the welding was carried out in compliance with a documented F x--]Yes =No <br /> quality control procedure to ensure that all discs are retrieved,that openings <br /> in piping are smooth,that slag and other welding residue are removed,and that <br /> the internal diameters of piping are not penetrated? <br /> Cutouts Do you certify that you have a control feature to ensure that Yes =No. <br /> (discs) all cutouts(discs)are retrieved? <br /> Hydraulic Nameplate provided If no,explain <br /> data <br /> nameplate =Yes =No <br /> Date left in service with all control valves open <br /> Remarks <br /> Name of sprinkler contractor COAST TO COAST FIRE PROTECTION,INC. <br /> Tests witnessed by <br /> For property owner(signed) Title Date <br /> For sprinkler contractor(signed)' Title Date <br /> F- fire rshall(signe �tle Date <br /> Additional explanatio6gandnAleb <br /> #SPILL! <br />
The URL can be used to link to this page
Your browser does not support the video tag.