My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21989
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2021 12:46:00 PM
Creation date
3/24/2021 12:45:58 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS
Building Department - Doc Type
Permit
Permit #
19-21989
Building Department - Name
HENDRICKS,GLENDA
Address
6152 SILVER OAKS DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AN D E RS E N CORPORATION And�rsen. <br /> RENEWAL BY ANDERSEN SERIES .GLIDER WINDOW + <br /> lm wu1mtl��50avE Homes <br /> (NON-IMPACT) (NON-HVHZ) ��m,M <br /> PH:(651116E-5 FX:(6511160-SE65 <br /> DESIGN PRESSURE RATING z Fj B e <br /> o a yI J vi <br /> SIZE CONFIGURATION DESIGN PRESSURE SASH WIDTH RATIO H _ ' <br /> Ile <br /> GENERAL NOTES: s rR+Z> z p O- $ S <br /> 72"X 80" XO +40.0/-40.0 PSF 1:1 TABLE OF CONTENTS w z 3F <br /> 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND 96"X54" KID +40.0/-40.0 PSF 1:1 SHEET REVISION SHEET DESCRIPTION 3O Z d <br /> MANUFACTUREDTO COMPLY WITHTHE CURRENT EDITION Q p? z <br /> A d <br /> FLORIDA BUILDING CODE(FBC),EXCLUDING HVHZ AND HAS 96"X 72" XO +40.0/-40.0 PSF 1:1 1 - GENERAL NOTES&GLAZING DETAIL p a ]W <br /> BEEN EVALUATED ACCORDING TO THE FOLLOWING: 108"X54" XO +25.0/-25.0 PSF 1:2 2 _ ELEVATIONS W 3 m co M <br /> AAMA/WDMA/CSA 101/I.S.2/A410-08/11 0= <br /> 108"X 72" NO +20.0/-20.0 PSF � 1:2 3 - ELEVATIONS w <br /> <q <br /> 2. ADEQUACY OF THE EXISTING STRUCTURAL 56"X80" ( XO +40.0/-00.0 PSF 1:2 ui <br /> 4 <br /> 7 - ANCHOR LAYOUTS a <br /> CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING _ <br /> 4"X 54" XO +40.0/-40.0 PSF 1:2 <br /> AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF 5 - ANCHOR LAYOUTS F a <br /> WITHSTANDING AND TRANSFERRING APPLIED PRODUCT 74"X 72" XO +35.0/-35.0 PSF 1:2 <br /> LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE 48"X48" XX +40.0/-40.0 PSF 1:1 6 - VERTICAL SECTIONS REMARKS BY DATE <br /> ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF 7 - HORIZONTAL SECTIONS <br /> INSTALLATION. 72"X 80" XX +30.0/-30.0 PSF 1:1 <br /> 96"X54" XX +35.0/-35.0 PSF 1:1 8 - ANCHOR DETAILS <br /> 3. 1%AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND 9 - INSTALLATION NOTES&ANCHOR SCHEDULE <br /> ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE 95"X60" XX +35.0/-35.0 PSF 1:1 <br /> STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE 96"X 72" XX +20.0/-20.0 PSF 1:1 <br /> RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF orurxarRmr:RarnutmHonrorawRn.ahas <br /> RECORD FOR THE PROJECT OF INSTALLATION. 144"%54" XOX +30.0/-30.0 PSF 1:1:1 pIE 0511E mxwnOHsuus[iHswunOHmOeaRre <br /> FlI°M 111E R W IRFl.1FNf5 ORRIIID NERF W,A II<EHSED <br /> 144"X72" XOX +25.0/-25.0PSF 1:1:1 3/4"O.A.INSULATED FNGINRRORMdrtER9WLVREPARE5rtE5VEGnC <br /> 4. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A GLASS ralusEMRnITxaPo�SREsr. <br /> TOLERANCE OF t1/4 INCH OF THE DEPICTED LOCATION IN 84"X 60" XOX +40.0/-40.0 PSF 1:1:1 Digitally si Rdrtd@.yy Norero,P.E <br /> THE ANCHOR LAYOUT DETAIL(I.E.,WITHOUT 84"X80" XOX +35.0/-35.0 PSF 1:1:1 Reason 1V1RT s�6Eymant <br /> CONSIDERATION OF TOLERANCES).TOLERANCES ARE NOT EXTERIOR INTERIOR Dat�'18 .62. 'VV/jam <br /> CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE 144"X54" XOX +30.0/-30.0 PSF 1:2:1 `,� •,.•E ice' <br /> NIXi _ 144"_X-72" XOX + .0/".0PSF 1:2:1 <br /> S. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE 84"%60" XOX +40.0/-40.0 PSF 1:2:1 `�` * N 7 7 <br /> € GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR 84"XSO" KOX +35.0/-35.O PSF 1:2:1 SILICONE <br /> i ASPECIFICSITE.IF SITE CONDITIONS CAUSE INSTALLATION BACK BEDDING S /r OF ?or <br /> TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, DESIGN PRESSURE UPGRADE RATING i 1/2"GLASS 14j <br /> A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE I 1 BITE �iT - O 1 <br /> SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN SIZE CONFIGURATION DESIGN PRESSURE SASH WIDTH RATIO <br /> NON-HVHZAREAS. "� i ��/ O <br /> 56"X48" XO +61.0/-79.0 PSF 1:1 ` '7im #R11111gL1,ldc <br /> 6. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON 40"X 40" XO +81.0/-100.0 PSF 1:1 O�A PX_N.77 <br /> THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. <br /> 88"X"I XO +42.0/-43.0 PSF 1:1 GLAZING DETAIL �RAMU LSL <br /> $ 7. WINDOW FRAME MATERIAL:FIBREX&PVC 74"%72" %O +50.0/-50.0 PSF 1:1 FBPE¢HT.0<AU11HU ATI N.2UM <br /> IN ACCORDANCE WITH THE CURRENT EDITION FBC,WOOD 74'XW' XO +50.0/-65.0PSF 1:1 <br /> GLAZING NOTES: FLU. FL19563 <br /> B. <br /> COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED 108"X 72" XOX +26.0/-26.0 PSF 1:1:1&1:2:1 <br /> g OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN 1. GLASS TYPE&THICKNESS SHALL COMPLY WITH ASTM E1300 <br /> CHAPTER 23. 120"%64" KOK +28.0/-28.O PSF 1:1:1&1:2:1 REQUIREMENTS AS WELL AS APPLICABLE SAFETY GLAZING DATE: 11.07.18 <br /> 9. GLASS SHALL MEETTHE REQUIREMENTS OF ASTM E 1300 S6"X48" XOX +61.0/-79.OPSF 1:1:1&1:2:1 REQUIREMENTS PER THE FBC.TEMPER AND SAFETY GLAZING DWG.BY: CHK.BY: <br /> GLASS CHARTS.SEE SHEET 1 FOR GLAZING DETAILS. 74"X 64" XOX +50.0/-65.0 PSF 1:1:1&1:2:1 REQUIREMENTS SHALL BE REVIEWED ON A SITE SPECIFIC BASIS. RV I H FN <br /> P 108"X"I XOX +40.0/-40.0 PSF 1:1:1&1:2:1 2. SETTING BLOCK DUROMETER HARDNESS OF 70-9D(SHORE A)AS SCALE: NTS <br /> REFERENCED IN FBC CHAPTER 24. <br /> `yL -SEE FRAME DESCRIPTIONS ON SHEET 6&8 3. SETTING BLOCKS TO BE LOCATED AT 1/4 SPAN LENGTH FOR GLASS DWG.a: AW D243 <br /> 1. DP UPGRADE PRODUCT POSITIVE RATING IS DRIVEN WIDER THAN 36"AS PER FBC CHAPTER 24. SHEET: <br /> BY STRUCTURAL ONLY.WATER IS NOT INCLUDED. 4. D.L.O.AND DESIGN PRESSURES MAY NOT EXCEED MAX VALUES IN <br /> 2. DP UPGRADE PRODUCT MUST BE INSTALLED DESIGN PRESSURE TABLES ON SHEET 1. �I <br /> THROUGH FRAME ONLY,EXCEPT ON SILL WHERE llll <br /> JAMB CLIPS MUST BE USED. OF 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.