1_4 All panels are to bear the UL and NSF label. The panels shall reinforced plastic(FRP)or extruded aluminum for bearing strength.All <br /> incorporate cam lock type fasteners with reverse wing structural support doors shall have an anti-sweat heater wire around the entire perimeter <br /> as joining devices for the adjacent tongue and groove panels. Each of the door opening and under threshold. <br /> device is to consist of a cam action locking arm and a steel rod in �The heate�wire(standard in both coolers and freezers)shall provide <br /> adjoining panel so that by rotating the locking arm,the hook engages enough heat to prevent condensation.All conduit for the inner-wiring <br /> over the rod and the cam action draws the panel together.The resulting of the door panel shall be totally concealed in the polyurethane foam <br /> panel joints shall be sealed by a foamed-in-place, continuous one panel,exposed conduit is not acceptable. <br /> piece gasket. <br /> 1_5 Panel joints are to be precisely formed male and female tongue and 6_6 Door section to be field wired to surface mounted junction box on the <br /> interior door panel.The door size,location and swing to be as indicated <br /> groove shapes fabricated to force the male edge to contact the female in Specificatio s Drawings. <br /> edge, providing additional seal. The panel joint shall have a gasket <br /> which provides a positive seal that meets NSF standards.Gasket shall I Door harZare shall be highly polished chromium plated steel. <br /> be "locked" to the skins and run in a continuous piece, completely Hardware shall include a spring actuated door closer,field adjustable <br /> around the panel with only one break to provide the optimal seal. cam lift hinges, one spring hinge & deadbolt locking handle with <br /> 2.0 INSULATION independent k I y/padlock feature and inside safety release.All hardware <br /> shall be attached to extra large 1/2 inch thick,nonconducting synthetic <br /> 2_1 Insulation shall be a full 4 inches or 5 inches thick, UL Class 1 tapping plate <br /> rigid foamed-in-place HFC-245fa polyurethane with a minimum 2.15 Ibs/ 6_8 Digital thermometer calibrated to indicate interior walk-in temperature <br /> cubic foot density. Foam polyurethane shall be injected into the panels shall be provided with each entrance door. <br /> by means of a high output,high impingement mixer. <br /> 2_2 The R-values for 4"HE panels are: �High output low profile LED light with approximately twice the light <br /> output of a standard 60W incandescent or 13-15W CFL,guaranteed for <br /> Cooler: 5 years or 35,000 hours. Light is positioned above the door to prevent <br /> Walls/Ceilings R-value 25 <br /> interference th shelving or product. Locate light switch with pilot light <br /> Doors R-value 25 <br /> adjacent to door, on exterior handle side of door section,with all inner <br /> Freezer: wiring in conduit concealed inside the door section and terminated at <br /> Walls/Ceilings R-value 32 a surface mounted junction box on the interior door frame.Fixture shall <br /> Doors R-value 32 Floors R-value 28 operate on 120 VAC. <br /> 7.0 INSTALLATION AND MAINTENANCE: <br /> 2_3 Insulation shall be 90%closed cell structure. Flame spread rating <br /> according to ASTM E-84/UL 723 shall be 25 or less. 7_1 Included with each walk-in shipment is a complete set of installation <br /> 2_4 The use of R-12 and/or R-22 as a blowing agent is specifically instructions covering all phases of panel erection, accessories, and <br /> prohibited. maintenance procedures. <br /> 3.0 FLOOR STYLES: 6.0 APPROVALS: <br /> 3 1 Less floor 4"wall walk-ins shall be supplied with PVC extruded floor <br /> have <br /> 81 Walk-in construction is approved by NSF International and shall <br /> sealers with semi-flexible edges,which seal to floor without the use of _ the NSF(seal on the door section. <br /> exposed fasteners.Sealer shall encase the wall panel on both interior 8-2 Walk-in panels shall have a UL flame spread rating of 25. <br /> and exterior surfaces with a flexible rubber collar a minimum of 3"high 8_3 The door(section shall be UL and CSA approved as an electrically <br /> from finished building floor.Sealer shall meet NSF requirements for floor approved assembly. <br /> cove molding.Additional less floor options include female bottom rail <br /> walls for 4"and 5"thick walk-ins and various height foam sealers for 4" 8_4 City of Houston approved,Oregon State approved,State of Wisconsin <br /> thick walk-ins.Consult factory for detailed specifications. Building Product approved,USDA accepted. <br /> 3.2 With floor walk-ins shall be a full 4 inches thick with one piece 9.0 WARRANTIES: <br /> foamed-in-place edge caps.Edge caps include metal formed adhesion 9.1 Manufacturer shall provide a written warranty to the owner stating <br /> edges which result in the edge caps being a foamed integrated member the product is free from defects or workmanship under normal use and <br /> of the floor panels.Glued-in-place edge caps are not acceptable.Floor service.Warranty shall become effective following the acceptance date <br /> panels shall be designed to withstand uniformly distributed loads of 800 and cover the insulated panels for a period of fifteen years and parts for <br /> pounds per square foot.The joint between the floor and wall shall form a period of 18 months. <br /> a NSF approved 45'angle to allow for easy cleaning. <br /> 10.0 QUALITY ASSURANCE: <br /> 4.0 CEILING PANELS: <br /> 10.1 To insure the finest quality in material and workmanship the above <br /> 4_1 Ceiling panels shall be a full 4 inches or 5 inches thick with one piece specifications shall be held in full compliance.Please specify the walk-in <br /> foamed-in-place edge caps.Edge caps include metal formed adhesion cooler or freezer is to be as manufactured by Nor-Lake,Incorporated. <br /> edges which result in the edge caps being a foamed integrated member 10.2 Contact Nor-Lake, Incorporated for a copy of the most detailed <br /> of the ceiling panels.Glued-in-place edge caps are not acceptable. <br /> Specification Manual available in the Foodservice Industry. <br /> 4_2 Metal face skins are to incorporate seams using a double 90'bend <br /> at a maximum width of two feet for additional strength.The joint between 11.0 SITE CONDITIONS: <br /> the ceiling and wall shall form a 45°angle to allow for easy cleaning. 11_1:To assure proper operation, site conditions should be controlled. <br /> 5.0 FINISHES: The walk-in product should be in a well ventilated location. Indoor <br /> ambient conditions should be controlled, relative humidity between <br /> 5.1 The interior and exterior walls and interior ceiling shall be supplied 30%-60%and maintaining a dew point of 50OF(or less). <br /> with 26 gauge corrosion resistant stucco embossed coated steel.The <br /> interior floor surface(when applicable)shall be.100 smooth aluminum. <br /> Other finisheds are available. <br /> 6.0 DOOR CONSTRUCTION: <br /> 6_1 Entrance door shall be in fitting,flush design.The door section shall ` <br /> provide a full 4 inches or 5 inches of polyurethane HFC-245fa insulation, <br /> construction and finish shall be the same as the adjoining wall panels. _ <br /> 6_2 The door shall be 4 inches thick,constructed to incorporate heavy <br /> duty,molded ABS breaker strip,which is permanently foamed-in-place. <br /> Bottom of door shall seal with double sweep gaskets,uniquely designed Im tj wo <br /> Pa <br /> to provide complete seal between door,threshold,and doorjamb. 21.8thndex. <br /> 6_3 Doorjamb to be a fully coved,extruded,welded,structural anodized Food Service Equipment Group <br /> aluminum,rigid frame design for easy cleaning and maintenance. Revision Date:4/19 <br /> 9 9 Y 9 All specifications subject to change without notice. <br /> 6.4 Threshold plate provided shall be constructed of fiberglass 02019 Nor-Lake,Inc.A division of Standex International ©2019 NOR-LAKE,INC. <br /> Corp.All rights reserved.Printed in the USA. Part Number:090773 <br />