FORM"R405-2017 <br /> MANDATORY REQUIREMENTS- (Continued) <br /> O R403.6.1.1 Cooling equipment capacity.(continued) The published r AHRI total capacity is a nominal,rating-test value and <br /> shall not be used for equipment sizing.Manufacture's expanded perforrrr ce:d=, shall be used to select cooling-only equipment.This <br /> selection shall be used to select cooling-only equipment This selection sh I based on the outdoor design dry bulb temperature for the <br /> load calculation(or entering water temperature for water-source equipin t�,.the blower cfm provided by the expanded performance data, <br /> the design value for entering wet bulb temperature and the design value toy entering dry bulb temperature. <br /> Design values for entering.wet bulb and dry bulb temperature shall be for indoor dry bub and relative tumidity used for the load <br /> calculation and shall be adjusted for return side gams if the return duct(s)is installed in an unconditioned space. <br /> Exceptions: <br /> 1. Attached single-and multifamily residential equipment sizikc 1 may be selected so that its cooling capacity is less than the <br /> calculated total sensible load but not less than 80 percent of at load. <br /> 2. When signed and sealed by a Florida-registered engineer,in'attached single-and multifamily units,the capacity of <br /> equipment may be sized in accordance with good design praMice_ <br /> O R403.6.12 gating equipment rapacity <br /> • R403.6.12.1 Heat pumps. Heat pumps sizing shall bs based on cooling requirements as calculated according to Section <br /> R403AA.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling bad. <br /> • R40&6.122 Electric resistance furnaces. Electric resistance fu Itnaces shall be sized within 4 kW of the design <br /> requirements:calculated according to the procedure selected in Section R403.6.1_ <br /> R403.6.1.2:3 Fossil fuel heating equipment. The capacity of-"I fuel heating equipment with natural draft atmospheric burners <br /> shall not be less than the design bad calculated in accordance with Section R403.6.1. <br /> O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an <br /> intermittent basis,such"as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to <br /> prevent continuous space coaling or heating within that space by one or made of the following options: <br /> 1. A.separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. <br /> 2 A variable rapacity system sized for optimum performance during base load periods is utlized. <br /> O R41M7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections <br /> C403 and C404 of the Commercial Provisions in lieu of Section R403. <br /> O R4032 Snow merit system controls(Mandatory). Snow and ice-melting systems supplied through energy service to the building,shall <br /> include automatic controls capable of shutting off the system when the pavement'temperature is above 55*F,and no precipitation is failing <br /> and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. <br /> R403.9 Swimming pools,in-ground spa 'and portable spas(Mandatory).- The energy requirements for residential pools and <br /> ingreund spas shall be as specified in Sections R403.9.1 through R403.9.3 and in a rdance with ANSI/APSP-15.The energy <br /> requirements for portable spas shall be in accordance with ANSI/APSP-14. <br /> O R40SAI tool and spa heaters. All pool heaters shall be equipped with readily accessible on-off switch that is mounted <br /> outside the heater to allow shutting off the heater without adjusting the thermostat setting. <br /> 1i403.9.1.1 Can and oltdired pool and spa heaters. All gas and."red pool and space heaters shall have a minimu m <br /> thermal efficiency of 02 percent for heaters manufactured on or after April 16,203 when tested in accordance with ANSI Z 21.56. <br /> Pool heaters fired by natural gas or LP gas shall not have continuous)i bu rninq pilot fights. <br /> R403.9.12 Heat pump pool heaters. Heat pump pool heaters shill have a minimum COP of 4.0 when tested in accordance <br /> with AHR11160,Table 2,Standard.Rating Conditions-Low Air Temperature.A test report from an independent laboratory is <br /> required to verify procedure compiiarhce.Geothermal swimming pout h6at pumps are not required to-meet this standard. <br /> O R403.9.2 Time switches. rime switches or other control method that can automatic ally turn off and on heaters and pumps according to a <br /> preset schedule shall be installed on all heaters and pumps_Heaters,pum and motors that have built in timers shall be deemed in <br /> compliance with this equipment <br /> Exceptions: <br /> 1. Where public health standards require 24-hour pump operatio <br /> 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. <br /> 3. Where pumps are powered exclusively from on-she renewrableigeneration. <br /> O R403.9.3 Covers. Heated swimmng pools and iriground permanently installed spas shall be equipped with a vapor-retardant cover on or <br /> at the water surface or a liquid cover or other means proven to reduce heat W . <br /> Exception: Outdoor pools deriving over 70 percent of the energy for I eating from site4ecovered energy,such as a heat pump or <br /> solar energy source computed over an operating season. <br /> 0 RR404.1 Lighting equipment(Mandatory-). A minimum of 75 percent of the lamps in permanently installed fighting fixtures shall be <br /> high-efficacy lamps or a minimum of 75 percent of permanently installed fighting fixture shall contain only high efficacy lamps. <br /> Exception:- Low-voltage fighting shall not be required.to utilize high cy lamps. <br /> 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have eantinueusly burning pilot tights <br /> O R40:2 Performance;ONLY. All duds not entirety inside the building thermal envelope shall be insulated to a minimum of R-6. <br /> O R405.2.1 Performance-ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and bears type or <br /> concrete deck roofs do not have suffecem space,R-10 is allowed. <br /> 0724120191:09:49'AM EnergyGauge®USA-F1aRes2017.Section R405.4.1 Comprranrt Software Page 3 of 3 <br />