My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22223
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22223
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:27:28 AM
Creation date
3/25/2021 10:27:23 AM
Metadata
Fields
Template:
Building Department
Company Name
FRATERNAL ORDER OF EAGLE
Building Department - Doc Type
Permit
Permit #
20-22223
Building Department - Name
FRATERNAL ORDER OF EAGLE
Address
38421 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Application <br /> Kidde VS Series life safety systems are powerful intelligent solutions of strobes to UL 1971 standards. For Genesis devices,enabling <br /> for small to mid-sized buildings.Advanced intelligent technology this feature allows horns to be silenced while strobes on the same <br /> delivers the benefits of flexible system installation,while clean and two-wire circuit continue to flash until the panel is reset. <br /> easy-to-operate user interfaces make panel operation and system <br /> maintenance quick and intuitive. Flexibility built right in <br /> Two fully-programmable front panel switch/LED combinations provide <br /> The smart choice an added measure of flexibility.Their slide-in labels take the mystery <br /> Electronic addressing eliminates the tedium of setting dipswitches, out of custom applications,and present a clean finished appearance. <br /> and automatic device mapping ensures that each device resides <br /> on the system at its correct location. Meanwhile,innovative pro- Perfect for retrofits <br /> gramming allows the designer to customize the system to pre- Kidde VS Series control panels are particularly well-suited to <br /> cisely suit the needs of the building owner. retrofit applications.All connections are made over standard wiring <br /> -no shielded cable required.This means that in most situations <br /> Reliability you can count on existing wiring can be used to upgrade a legacy control panel <br /> The inherent fault-tolerant characteristics of Analog/Address- to VS technology without the expense or disruption of rewiring <br /> able Technology boosts the reliability of Kidde fire alarm systems. the entire building.VS control panels also support the ingenious <br /> When combined with VS Series smoke and heat detectors,these RZI16-2 zone module,which adds up to 16 conventional circuits <br /> systems deliver a level of dependability not previously available and two NACs.This combination easily accommodates new intel- <br /> for small to mid-sized applications,All Kidde systems are built to ligent detection alongside existing conventional circuits, making it <br /> exacting reliability benchmarks and meet international standards an superior solution in the retrofit market. <br /> for quality,in addition to agency listings for dependability. <br /> Scalable IP and Cellular Communications <br /> Clear-cut remote annunciation Several popular third-party IP/Cellular communicators have been <br /> Remote annunciation is a strong suit of the VS Series fire alarm tested with the VS control panels and are compatibility listed to <br /> systems. Up to eight annunciators can be installed on a single UL864.The IP/Cellular communicators meet NFPA72 2013 edition <br /> system.Compatible annunciators include a range of LED and LCD requirements for sole or secondary transmission paths. Using IP/ <br /> models that provide zone or point annunciation, as well as com- Cellular communicators can reduce the cost of ownership by <br /> mon control capabilities.VS control panels also supports graphic eliminating POTS lines. Please see the VS control panel compat- <br /> annunciation with optional graphic annunciator interface modules. ibility documentation part number 3102354-EN for a full list of <br /> Each interface provides common control and 32 LEDs. compatible communicators. <br /> Signals with a difference A complete line of accessories <br /> VS Series NACs are configurable to fully support the advanced VS Series life safety systems are supported by a complete line of <br /> signaling technology of Kidde Genesis and Enhanced Integrity no- analog/addressable detectors, modules and related equipment. <br /> tification appliances.These devices offer precision synchronization Consult the Ordering Information section for details. <br /> Programming and remote diagnostics Dimensions <br /> Kidde VS Series life safety systems are simple to set up,yet offer 0) <br /> r21 tsl fat <br /> advanced programming features that put these small building02� T iO3 Dr <br /> panels into a class of their own.The auto programming feature 01 O o 6 o o <br /> quickly gets the panel operational using factory default settings. (` t ® O <br /> Basic zone and point settings can be programmed through the O 1 O jo <br /> front panel interface,so the system is up and running in no time. t t O <br /> oa C IC <br /> For more advanced system configuration and correlation groups 01 t O Da � <br /> programming,VS Series systems interface to a PC running com- © _o O to <br /> patible VS-CU software.This option offers full system configura- <br /> tion in the familiar Windows®operating environment.Connection is <br /> made to a laptop through the panel's optional RS-232 communi- <br /> cations port,which can also be used to connect a system printer. <br /> Among the many innovative features of VS Series control panels t` 'I <br /> is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached <br /> 10/100 Base T Ethernet®network connection that permits access (2)Semi-Flush mounting Holes (4)Backbox with door and trim kit attached. <br /> to the control panel from any remote location with the correct <br /> communications protocols.The connection can be used to down- Panel dimensions,in(cm) <br /> load to the panel from the VS-CU,or upload and view system Model Dig I D2 ; D3 D4 D5' D6 D7 I D8 1 D9 <br /> reports using the VS-CU. vs4 28.0 3.85 9.0 22.0 15.75 10.25E4. <br /> 30.1 ; 2.7 <br /> (t1.1) (9.8) (22.8) (55.8) (40.0) L(26.0) p6.4) i (s.8) <br /> Available system reports include:Correlation groups, Device de- vs1 21.5 3.85 i 7.5 15.5 14.25 23.6 2.7 <br /> tails, Device maintenance, History, Internal status,System configu- (54.6) (9.8) 1 (19.0) (39.4) (36.2) (59.9) (6.8) <br /> ration, System status,Walk test, Dialer,and CO runtime. 'Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim idt.The trim kit <br /> y provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. <br /> 0 <br /> Page 2 of 8 DATA S f I F E r V85005-0135 � <br /> Not to Isaac; ;czr ir:.tail,'c;i<.si ;,;;;r a<>:_ issuel.3 � <br />
The URL can be used to link to this page
Your browser does not support the video tag.