My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22239
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22239
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:38:01 AM
Creation date
3/25/2021 10:38:00 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
20-22239
Building Department - Name
LENNAR HOMES LLC
Address
3212 NUBBIN RIDGE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> w <br /> D <br /> . Q <br /> f <br /> Single Family Dwelling <br /> Plan Review Com nents <br /> 1. F.F.E; shall be a minimum of 8" above the road elev tion and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401.3o f the F. C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides f driveway thru the sidewalk shall have <br /> expansion m4terial. <br /> 6. All setbacks shall be met. <br /> 7. All property markers sliall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9. No electric,.plumbing, mechanical, or framing shall pe covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of th F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303 A of the F.B. <br /> 12. Water heaters shall comply with section P607.3 of tl4e R.B.C. <br /> 13. Foundation supports for A/C units shall be raised_ at ,east 3" above finished grade. M1308.1 <br /> 14. Return air iri all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance w th R3 I3.I of the F.B.C. <br /> 16. All glazing requirements are to be in accordance wi h R308.4.of the F.B.-C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backe in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new c ristrdction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be i stalled in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be se crate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.