My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22240
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22240
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:38:32 AM
Creation date
3/25/2021 10:38:31 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
20-22240
Building Department - Name
LENNAR HOMES LLC
Address
3176 NUBBIN RIDGE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D <br /> Q <br /> Single Family D elling <br /> Plan Review Com ents <br /> 1. F.F.E. shall be a minimum of 8" above the road eleva 'on and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401:3 of the F. C. <br /> 3. Compaction test required if 24"or more of fill dirt is rought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides o driveway thra the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> -7. All-property markers shall be uncovered and marked t time of first inspection. <br /> 8. All A.D.A.requirements shall be met: <br /> 9. No electric,plumbing, mechanical, or framing shall b covered without an inspection and <br /> approval first. <br /> 106 All Garages shall comply with section R302.6 of the IB.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical.damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at le st 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M.1620.4 <br /> 15. Smoke detectors are to be installed in accordance witt. R313.1 of the F.B.C. <br /> 16. All glazing requirerrients are to be in accordance"with 308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall not be used as a backer i showers or tubs. R702:4.2 F.B.C. <br /> i 0. Combination-type AFCI breakers are required at all to ations requiring an AFCI type breaker. <br /> -20. Carbon monoxide alarms will be required in new cons" . ction that uses fossil-burning heating <br /> or appliances or an attached garage." They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.