Laserfiche WebLink
r, <br /> D <br /> 4 <br /> f <br /> Single Family D elling <br /> Plan Review Comiments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevat on and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24" or more of fill dirt is rought in at any one place. <br /> 4: Tie in survey required before pouring concrete: <br /> 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be in <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A.'requirements shall be met: <br /> 9. No electric, plumbing., mechanical, or framing shall b covered without an inspection_ and <br /> approval first. <br /> 10. All,Garages shall comply with section R302.6 of the F.B.C. (Fire'Separation). <br /> 11. Appliances shall not be installed in a location where s 4bject to mechanical damage unless <br /> protected by approved barriers. M303;4 ofthe F:B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 - <br /> 14: Return air in all bedrooms. F.B:C. M1620:4 <br /> 1.5. Smoke detectors are to be installed in accordance wit R3111 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B:C: <br /> 17. All means of egress are to be in accordance with PO I of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 19. Combination-type AM breakers are required at all 1.c cations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new com truction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.G. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />