My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22256
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22256
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:50:22 AM
Creation date
3/25/2021 10:50:19 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22256
Building Department - Name
DR HORTON INC
Address
8029 SAIL CLOVER LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 0 <br /> 1 N=>S Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 164.7 ftz 0 0.6 0 <br /> 2 W=>E Exterior Concrete Block-Int Insul Main 4.0999 43 E 8 8 378.4 ftz 0 0.6 0 <br /> 3 S=>N Exterior Concrete Block-Int Insul Main 4.0999 39 8 8 8 343.8 ftz 0 0.6 0 <br /> 4 E=>W Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ftz 0 0.6 0 <br /> 5 N=>S Garage Frame-Wood Main 11 20 0 8 8 173.3 ftz 0.23 0.01 0 <br /> 6 W=>E Garage Frame-Wood Main 11 15 4 8 8 132.9 ftz 0.23 0.01 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>S Insulated Main Non .4 3 6 8 20 ftz <br /> 2 N=>S Wood Main Non - .46 2 8 6 8 17.8 ftz <br /> WINDOWS <br /> Orientation shown is the entered orientation => .chan ed o As Built rotated 180 degrees). <br /> / Wall Overhang <br /> V .• # Ornt ID Frame Panes NFRC U-Factor SHGC I p Area Depth Separation Int Shade Screening.. <br /> 1 N=>S 1 Vinyl Low-E Double Yes 0.34 -0.31 31.0 ftz 1 ft 0 in 4 ft.1 in None Exterior 5 . <br /> 2 N=>S 1 Vinyl Low-E Double Yes 0.34 0.31 3.0 ftz 3 ft 8 in 0 ft 0 in None Exterior 5 <br /> 3 W=>E 2. Vinyl Low-E Double Yes 0.34 0.31 15.5 ftz 1 ft 0 in 0 ft 9 in None - Exterior 5 <br /> .4 S=>N -3 Vinyl Low-E Double Yes 0.34 0.31 l' 62.0 ftz 1 ft 0 in 0 ft 9 in None Exterior 5 <br /> 5 S=>N 3 Metal Low-E Double Yes 0.55 0.34 IN 40.0 ftz 8_ft 0 in 0 ft 8 in None Exterior 5 <br /> 6 E=>W 4 Vinyl Low-E Double Yes 0.34 0.31 1, 15.5 ftz 1 ft 0 in 0 ft 9 in None Exterior 5 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 430.0128 ftz 430.0128 ftz 46.6 ft 8.67 ft 0 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000386 1849 101.51 190.9 .1459 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficie cy Capacity Block Ducts <br /> 1 Electric Heat.Pump/ None HSPF: .2 28.6 kBtu/hr 1 sys#1 <br /> 1 1/5/201 9 1 1:45 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th E ition(2017) Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.