Laserfiche WebLink
23. Tamper- Resistant.Receptacles in accordance with 4 6.11 of the.2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. 14403.5.3Hof Water pipe insulation . <br /> insulation for.hot water pipe with a minimum thermal resist nce (R.value) of R-3 shall be applied to the <br /> following: <br /> Piping�!. inch (1.9.1 mm)and larger in.nominal.diamete . . <br /> Piping;serving more than one dwelling unit. <br /> Piping located.outside the conditioned space.. <br /> Piping from the:water heater to a distribution manifold.. <br /> Piping located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other han demand recirculation systems: <br /> 25. Blower door test shall be provided before C.O: <br /> 26. A co bf the-energy cacls shall be with Oermit at al .times <br /> o inal.insulation re ort shall be rovided ivi ermit before inal <br /> 27. Co � - <br /> 28.No encePool or screen enclosure :is issued with Ih is perinit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />