Laserfiche WebLink
• • 1 <br /> 23. Tamper- Resistant Receptacles in accordance with 40 .11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall.be sodded before final at least 10. <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation. <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 3/a inch (19.1 mm) and larger in nominal diame_ter, <br /> Piping serving more than one dwelling unit. <br /> Piping located outside'the conditioned space. <br /> Piping from the:water heater to a distribution manifold.- <br /> Piping located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. . <br /> 26.A co o the ene' cacls shall be with permit at all times <br /> 27. CoPV.o t uial'insulation'report shall be provided Permit before rinal <br /> 28. No encePool or screen enclosure :is issued with.th s erniiz <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.- ational Electric Code (2016) <br /> i <br />