Laserfiche WebLink
D <br /> Q <br /> 1 <br /> i { <br /> Single Family Divelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides o driveway thru the sidewalk shall have <br /> ekpansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked k time of first-inspection. <br /> 8. All A.D.A."requirements shall be met: <br /> 9. No electric,.plumbing;mechanical,or framing shall b covered without an inspection.and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of theF.B.C. (Fire Separation).. <br /> 11. Appliances shall not be installed in a location where s abject to mechanical damage unless <br /> protected.by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with P,311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer iii showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AM type breaker. <br /> 20. Carbon monoxide alarms will be required in new con traction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be-installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />