Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016-N.E.0 <br /> 24. 1 ri accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation. <br /> Insulation for hot.Water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following:: <br /> Piping.-14 inch (1.9.1 mm)and larger_in.nominal diameter.. <br /> Piping serving more than.phe dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution manifold., <br /> Piping located under'a floor slab.. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C.O: <br /> 26. A copy of the eneney cacls shall be with perhiit at all times: <br /> 27. Cony of finatinsulation report shall be provided with permit befdre fnaL <br /> 28. No fence,pool or screen.enclosure :is issued with:this-bersnii; <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D:A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />