Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 NEC' <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.31-lot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: . <br /> Pip.ing.3/, inch (19.1 mm) and larger in nominal diame_ter.: <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space;. <br /> Piping from the:water heater to a'd.istribution manifold.. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be proOded before C.O. <br /> 26. A copy of the-enerQ'y cacls shall be.with permit at all times. <br /> 2Z Copy of final-insulation report shall be provided with per»:it before final <br /> 28. No fence, pool or screen enclosure .is issued with.thispermit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6ffi Edition <br /> R.O.W.-Right of way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />