My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22371
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22371
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 1:25:24 PM
Creation date
3/29/2021 1:25:22 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-22371
Building Department - Name
JENKINS,WAYNE & TAMMY
Address
5839 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL <br /> 1.THEPR PRODUCT <br /> FL#22300 WINFORCE DOUBLE HUNG WINDOW <br /> 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK <br /> EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMANVDMA/CSA APPROVED CONFIGURATIONS NON-IMPACT <br /> 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA DESIGN <br /> BUILDING CODE,6TH EDITION(2017). CONFIGURATIONS NOTED AS HVHZ HVHZ IMPACT <br /> APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE CONFIGURATION APPROVED PRESSURE RATING <br /> ACCEPTABLE FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. RATING LOCK NOTE: 1 LOCK ASSEMBLY <br /> 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT 54"x7T'EQUAL LITE YES +50/-50 PSF (ITEMS 23-25)ALLOWED FOR <br /> PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 24"x77"EQUAL LITE YES +50/-50 PSF 24"X7T'MAX.SIZE ONLY. ALL <br /> 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING ARE AS 45"x86"EQUAL LITE YES +50/-50 PSF OTHER CONFIGURATIONS <br /> LIMITED BY ASTM E-1300 GLASS TABLES,AND TESTED WATER AND REQUIRE 2 LOCK ASSEMBLIES <br /> STRUCTURAL PRESSURES. 53"x86"EQUAL LITE NO +40/-50 PSF NONE <br /> 4.THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE W/FULL SCREEN INSECT SCREEN NOTE: ALL <br /> THE INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE 53"x86"EQUAL LITE NO +50/-50 PSF SIZES EXCEPT 53"X86"MAY USE <br /> CONFIGURATIONS SHOWN IN THE ELEVATIONS. INSTALL PRODUCTS W/HALF SCREEN FULL SCREEN OR HALF SCREEN <br /> WITH MAXIMUM SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT, 42"x82"ORIEL NO +50/-50 PSF AT FULL DESIGN PRESSURE <br /> AND WITH FASTENER TYPE AS SHOWN IN THE DETAILS AND AS <br /> INDICATED IN TABLE 1. FOR FULL PRODUCT CONSTRUCTION DETAILS 54"MAX. <br /> SEE NCTL TEST REPORTS 210-4067-02/02A/03/03A,AND WINDOW WIDTH 6"MAX. 11"MAX.ON 24"MAX.WINDOW WIDTH <br /> 210-4083-03/04/05A/05C/06B/06C. 14"MAX.ON CENTER, <br /> 5.MINIMUM GLAZING IS INSULATING GLASS 1/8 ANNEALED+1/2"GED CENTER TYP FROM TYP <br /> STAINLESS STEEL INTERCEPT SPACER+1/8"ANNEALED,GLAZED WITH , . CORNER, 6"MAX.FROM <br /> GE SCS2801 SILICONE BACKBEDDING W/1/2"GLASS BITE. TYP. 1 CORNER,TYP. <br /> 6.THE 4/3 ALLOWABLE STRESS INCREASE FACTOR(SHORT-TERM J <br /> INCREASE FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS <br /> FOR THIS SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF O O <br /> ANCHORAGE INTO WOOD SUBSTRATE. a Co_j a 0D O <br /> 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS) O } ; O <br /> AND ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND w ~ ALL Ell� <br /> SHALL BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR W, M g xX W Cl) x <br /> AS APPROVED 13Y THE AUTHORITY HAVING JURISDICTION(AHJ). z <br /> BUCKING,OPENINGS,&BUCKING ASTENERS MUST BE PROPERLY W / Q = �w ¢2 Lucas <br /> DESIGNED&INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO io O Z o � ?� U z n 0 Turner <br /> O O CO O O 2017-12-28 <br /> 16:26+19:0 <br /> TRANSFER SUPERIMPOSED LOADS TO THE STRUCTURE. WITH y'` r� n <br /> O ' O 16:26+19:00 <br /> MASONRY OPENINGS,WOOD BUCKS ARE OPTIONAL. W 0a 0 Z_ W 0 _Z <br /> 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE 2 F_ n U I— n O <br /> COATED OR OTHERWISE PROTECTED TO PREVENT GALVANIC cn W v i�l w v <br /> REACTIONS. WOOD BUCKS,IF USED,SHALL BE PRESSURE TREATED, U U <br /> WITH EITHER A TREATMENT OR COATING COMPATIBLE WITH THIS `a�q°.�6£NgF`Y»r <br /> PRODUCT. SILL ANCHOR SILLANCHOR No 5$207 :ti <br /> 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING SPACING SPACING *: c <br /> SAME AS HEAD SAME AS HEAD # <br /> COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL ai ?� <br /> OTHER WINDOW MATERIALS. 9: srnTE oa <br /> 54"x77"EQUAL LITE ELEVATION 24"x77"EQ.LITE ELEV. °.'�� <br /> 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH �FS•L°ato.�v��.�' <br /> THESE DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BY A <br /> FLORIDA REGISTERED PROFESSIONAL ENGINEER ONASITESPECIFIC TABLE OF CONTENTS NORTHEAST BUILDING PRODUCTS <br /> BASIS. SHEET DESCRIPTION 4280 Aramingo Ave.,Philadelphia,PA 19124 7Z <br /> 11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER 1 NOTES,ELEV, Ph.(215)535-7110 www.camelotwindows.com 12/27/2017 <br /> INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE CONFIG.TABLE SHEET DESCRIPTION: DATE DRAWN: Lucas A.Turner,P.E. <br /> RESPONSIBILITY OF OTHERS AND ARE NOTADDRESSED BY THIS 2 ELEV.,GLAZING NOTES,ELEVATION 4/13/2017 FL PE#58201 <br /> DOCUMENT. 3 VERTICAL SECT. 1239 Jabara Ave. <br /> 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 4 HORIZ.SECTIONS SCALE: NTS REV:A North Port,FL 34288 <br /> ..SHEET4. 5 BOM,PART DWGS. DRAWING:FPA-WINF.ORCE-DH-NI. ... SHEET: 10175 Ph.941-380-1574 <br />
The URL can be used to link to this page
Your browser does not support the video tag.