GENERA <br /> NOTES <br /> 1.THEP PRODUCT <br /> WINFORCE HORIZONTAL SLIDER WINDOW <br /> 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK <br /> EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMANVDMAtCSA NON-IMPACT <br /> 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA APPROVED CONFIGURATIONS <br /> BUILDING CODE,6TH EDITION(2017). CONFIGURATIONS NOTED AS HVHZ <br /> APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE ACCEPTABLE DESIGN <br /> CONFIGURATION REQUIRED HVHZ RAPING <br /> FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. GLAZING* APPROVED PRESSURE KITING <br /> 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT RATING <br /> PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 74"x63"XX 2SL TYPE A YES +50/-50 PSF <br /> 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING ARE AS LIMITED 84"x66"XX 2SL TYPE B YES +50/-50 PSF <br /> BY ASTM E-1300 GLASS TABLES,AND TESTED WATER AND STRUCTURAL PRESSURES. 104"x66"XOX EQUAL LITE TYPE A YES +50/-50 PSF <br /> 4.THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE THE 93"x66"XOX 1/4-1/2-1/4 TYPE A SASH YES +55/-55 PSF NONE <br /> INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE TYPE B FIXED <br /> CONFIGURATIONS SHOWN IN THE ELEVATIONS. 'X'INDICATES OPERABLE <br /> PANEL,'O'INDICATES FIXED PANEL. INSTALL PRODUCTS WITH MAXIMUM 104x66"XX 2SL TYPE B NO +401-40 PSF <br /> SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT,AND WITH <br /> FASTENER TYPE AS SHOWN IN THE DETAILS AND AS INDICATED IN TABLE 1. L104'k66"XOX 114-1/2-1/4 TYPE B NO +40/-40 PSF <br /> FOR FULL PRODUCT CONSTRUCTION DETAILS SEE NCTL TEST REPORTS <br /> 210-4067-01/01A/01B/01C,AND 210-4081-01B/01C/02B/03B/04A/04C *SEE GLAZING DETAILS,SHEET 2 <br /> 5.APPROVED MINIMUM GLAZING IS AS SHOWN IN GLAZING DETAILS ON <br /> SHEET 2 AND AS SPECIFIED IN ALLOWABLE CONFIGURATIONS TABLE ON INSTALLATION 74"MAX.WINDOW WIDTH <br /> THIS SHEET. FASTENER 10-1/2"MAX 6"MAX. <br /> 6.THE 4/3 ALLOWABLE STRESS INCREASE FACTOR(SHORT-TERM INCREASE LOCATION,TYP. FROM <br /> FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS FOR THIS ON CENTER, CORNER, <br /> SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF ANCHORAGE TYP." TYP <br /> INTO WOOD SUBSTRATE. <br /> 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS)AND --� <br /> ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND SHALL 32-5/8"MAX F <br /> BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR AS ' DLO,TYP. C7 APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). BUCKING, n <br /> OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY DESIGNED& 0 uj <br /> = Lucas <br /> INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO TRANSFER X X 5: <br /> SUPERIMPOSED LOADS TO THE STRUCTURE. WITH MASONRY OPENINGS, x w �,�O Turner <br /> WOOD BUCKS ARE OPTIONAL. ¢Z Z 2018-03-13 <br /> 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE COATED O it 21:43+20:00 <br /> OR OTHERWISE PROTECTED TO PREVENT GALVANIC REACTIONS. WOOD CO U w <br /> BUCKS,IF USED,SHALL BE PRESSURE TREATED,WITH EITHER A W 0 <br /> n ..�`'9 <br /> TREATMENT OR COATING COMPATIBLE WITH THIS PRODUCT. - t0� . ticFnrS,• ,� y <br /> 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING Z SILL ANCHOR SPACING <br /> COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL OTHER O SAME AS HEAD = �'" g267 '' 8 <br /> e*• * ,�: <br /> WINDOW MATERIALS. = <br /> 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH THESE 74"X63"XX 2SL ELEVATION ;'P': Srate of <br /> DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BY A FLORIDA ~�p"F'=cL p R�pP' J <br /> REGISTERED PROFESSIONAL ENGINEER ON A SITE-SPECIFIC BASIS. TABLE OF CONTENTS <br /> 11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER SHEET DESCRIPTION NORTHEAST BUILDING PRODUCTS <br /> INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE 1 NOTES,ELEV., 4280 Aramingo Ave.,Philadelphia,PA 19124 i`y <br /> RESPONSIBILITY OF OTHERS AND ARE NOTADDRESSED BY THIS CONFIG.TABLE Ph.(215)535-7110 www.camelotwindowsmm 3/12/2018 <br /> DOCUMENT. 2 ELEV.,GLAZING SHEET DESCRIPTION: DATE DRAWN: Lucas A.Turner,P.E. <br /> 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 3 XOX ELEV.SHEET 5. 4 VERTICAL SECT. NOTES,ELEVATION 4/13/2017 FL PE#58201 <br /> 5 HORIZ.SECTIONS SCALE: NTS REV: 1239 Jabara Ave. <br /> B North Port,FL 34288 <br /> 6 BOM,PART DWGS. DRAWING:FPA-WINFORCESL-NI. .- SHEET 1 OF 6. ..Ph.941-38071574 <br />