My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22386
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22386
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 1:32:22 PM
Creation date
3/29/2021 1:32:20 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
20-22386
Building Department - Name
HIDDEN RIVER HO ASSOC INC
Address
3065 NUBBIN RIDGE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TSC38-D <br /> TSC MODEL 38-D <br /> DUPLEX PUMP CONTROL PANEL <br /> Panel meets or exceeds Florida Department of Environmental Protection—FDEP (FAC 17-604) <br /> The control panel shall be UL-508-A Listed and operate (2) electric submersible pumps on a low <br /> voltage (5 V DC) intrinsically safe control system (per FDEP/ 10 STATES STANDARDS) <br /> A. Fiberglass Enclosure-NEMA 4 X—exterior, rain &watertight with Lockable Hasp <br /> The enclosure shall have an aluminum interior"dead front"panel door and a factory supplied back plate that <br /> allows components to be securely mounted. The dead front door shall have a 115 volt GFI duplex <br /> receptacle. Run lights and control switches shall be mounted on the DUPLEXOR control device. <br /> (The use of 120-volt controls is not allowed). <br /> B. High Water Alarm System-Light and Horn-A flashing red light in a weatherproof fixture shall be <br /> mounted to the side of the enclosure. An audible weatherproof alarm bell/horn with an exterior alarm- <br /> silencing button shall de-activate the audible but maintain the visual alarm until the fault is corrected. <br /> C. DUPLEXOR(ALTERNATOR) Level Control System -Intrinsically Safe Low Voltage- <br /> s volt DC operation <br /> The level control system shall be a 12 pin,plug-in, field replaceable solid-state device. The DUPLEXOR <br /> shall ALTERNATE PUMPS and include (2)H-O-A(Hand-Off-Automatic) switches,LED indicating lights <br /> for each pump and all 4 float switches. The DUPLEXOR shall have a lead-lag alternator selector switch and <br /> alternator test switch. <br /> The DUPLEXOR control system will start, stop and alternate pump motors in response to the wet well level. <br /> On a falling level, lowest float switch(FSI- PUMP OFF) shall close, locking the pumps into a common <br /> "pumps off'. As the level rises, second float switch(FS2-PUMP ON) shall close at the "lead pump on" <br /> level and automatically alternate and select the lead pump. Should the liquid level continue to rise faster <br /> than one pump can handle,the third float switch(FS3-LAG/BOTH PUMP ON) shall close at the"lag <br /> pump on" level starting the lag pump. As the pumps run, lowering the liquid level,the switches shall open in <br /> reverse order. The fourth float switch(FS4-HIGH WATER ALARM) shall activate only if the liquid <br /> level continues to rise, causing both the audible alarm and the light(visual) alarms to activate. <br /> The DUPLEXOR shall provide for time delay starting of the lag pump-preventing both pumps from starting <br /> at the exact same time. This feature prevents an amp rush that could cause a nuisance trip. <br /> In the event of a float switch failure-the DUPLEXOR shall provide operation to keep the pump station from <br /> overflowing by operating on any (2) switches. <br /> D. PANEL FEATURES-REQUIRED BY F.D.E.P. OR NATIONAL ELECTRICAL CODE (N.E.C.) <br /> Weatherproof schematic wiring diagram shall be permanently affixed to enclosure door. Terminal blocks <br /> shall be located far enough away from the enclosure side(s)to permit convenient connection of incoming <br /> wires per N.E.C. code. <br /> F/FS/TSCV/ST/38DSSPane1 <br /> Rev 10/04 pgI <br />
The URL can be used to link to this page
Your browser does not support the video tag.