Laserfiche WebLink
R W R W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the Building Industry <br /> C P.O.Box 230 Vatriao,FL 33595 Phone 813.659.9197 <br /> Florida Board of Professional Engineers Certificate of Authorization No.9813 <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> NewSouth Window Solutions 9400 Single Hung Window <br /> Windows Single Hung 4901 Oak Fair Blvd w/Flange <br /> Tampa,FL 33610 "Non-Impact" <br /> 813 626.6000 <br /> Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System 1D#1998)for <br /> NewSouth Window Solutions,based on Rule Chapter No.61G20-3,Method I of the State of Florida Product Approval, <br /> Dept.of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt,P-E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 61h Edition(2017)Florida Building Code(FBC)excluding the"High <br /> Velocity Hurricane Zone"(HVHZ). <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or <br /> stucco. <br /> 3.When used in areas requiring wind borne debris protection this product is required to be protected with an impact resistant covering that <br /> complies with FBC Sections 1609.1.2&R301.2.1.2. <br /> 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-16851.2 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-16851.2 for size and design pressure limitations. <br /> Supporting Documents. <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> ATI C7180.07-50144 AAMA/WDMA/101/I.S.2/A440-08 Architectural Testing,Inc. Michael D.Stremmel. P.E. <br /> TEL 02031566 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. <br /> 2. Drawing No. Prepared by Signed&Sealed by <br /> No.FL-16851.2 RW Building Consultants.Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 3. Calculations Prepared by Sianed&Sealed by <br /> Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. Quality Assurance <br /> Certificate of Participation issued by National Accreditation and Management <br /> Institute,certifying that NewSouth Window Solutions is manufacturing <br /> products within a quality assurance program that complies with ISO/IEC ,,��tttltilfl111��4 <br /> 17020 and Guide 53. �`C c IV <br /> s� <br /> No 43409 <br /> 90 STATE O <br /> C s p <br /> R i <br /> qfONAl������ Lyndon F.FL PE NoItl43409 <br /> 10I12/2017 <br /> Sheet 1 of 1 <br />