Laserfiche WebLink
REVISIONS <br /> REV DESCRIPTION DATE APPROVED <br /> A REVISED INSTALLATION DETAILS 09/16/15 R.L. <br /> B I REVISED PER NEW REQUIREMENTS 08/06/19 R.L. <br /> NOTES: 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH <br /> 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM EDGE <br /> REQUIREMENTS OF THE FLORIDA BUILDING CODE. DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. <br /> 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH <br /> TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. <br /> RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. <br /> 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 17. ALL FASTENERS TO BE CORROSION RESISTANT. <br /> 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR <br /> ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN <br /> INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: <br /> MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 <br /> 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. <br /> FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). <br /> BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM <br /> MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 19. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS <br /> 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN <br /> N SHEET 2. <br /> COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF <br /> THE ARCHITECT OR ENGINEER OF RECORD. <br /> 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO_THAT FULL FRAME SUPPORT IS <br /> PROVIDED. <br /> 8. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE ALL WORK SHALL COMPLY WITH PREVAILING <br /> SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4... CODES FLORIDA BUILDING CODE, <br /> 9. SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE LOADS, NATIONAL ELFCTRIC CODE, <br /> LOCATED AND APPLIED IN A THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. <br /> 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. AND THE CITY OF ZEPHYRHILLS <br /> 11. FRAME MATERIAL: EXTRUDED RIGID PVC. ORDINANCES <br /> 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. <br /> 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE /! <br /> DEBRIS REGIONS. REVIEW DAY E I�__94471. <br /> 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH <br /> SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE CITY OF ZEPHYRHI <br /> ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. PLAN EXAMINER <br /> SIGNED:0810612019 <br /> MI 650 WINDOWS AND <br /> MAD ET STREET <br /> LLC. <br /> GRATZ, PA 17030-0370 ``,••�.`GENSF•S+ <br /> SERIES 3240/3540 FINLESS PVC SH WINDOW A-TAT <br /> 0POF <br /> STEEL REINFORCED — NON—IMPACT 52" X 62"TABLE OF CONTENTS NOTES ��0, �{{L[Q` <br /> SHEET N0. DESCRIPTION DRAWN: DWG N0. REV ��'��.5'PZORIDt G���� <br /> 1 NOTES SCALE DATE 08 02269 B �QNAL`E� <br /> 2 ELEVATION NTS 01/09/14 1 OF 6 <br /> 3 — 5 INSTALLATION DETAILS L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. <br /> 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 <br /> 6 COMPONENTS 434-688-0609 rllomas�Momaspe.com <br />