MODEL DESIGNATION: Sir ionton Double Hung Series 43-17 Vinyl Window
<br /> MAXIMUM OVERALL NOMINAL SIZE: Sea Size Chart Vp.��GHNSF.P`'.� 12/01/2017
<br /> r LUCAS A. TURNER, P.E.
<br /> DESIGN PRESSURE RATING: Sea Size Chart No 58201 FL PE // 58201
<br /> TURNER ENGINEERING h
<br /> USABLE CONFIGURATIONS: X o
<br /> CONSULTING, INC. -
<br /> X GTt 1 STATE OF ;"W: (COA # 29779)
<br /> 1239 JABARA AVE.
<br /> NORTH
<br /> �`tl '13PPH. 94OR380-1574 8 GENERAL DESCRIPTION: Th a head, ill,and sie jambs ae extruded PVC.The wal hr gh which the anchor screwrpenelrales Is a m nimumlofh0,1425s g4S��NA�
<br /> TABLE 1: INSTALLATION FASTENERS TABLE
<br /> ID SUBSTRATE TYPE ANCHOR TYPE MIN. EMBED MIN EDGE
<br /> DISTANCE
<br /> A CONCRETE (2 KSI MIN.) 3/16" ITW TAPCON 1-1/2" 1 1 8"
<br /> B HOLLOW OR GROUT—FILLED CMU 3 16" ITW TAPCON V, 2"
<br /> ASTM C90 117 PCF MIN. /
<br /> C 2X MIN. SOUTHERN PINE WOOD 3/16" ITW TAPCON 1-3/8" 3/4"
<br /> G=0.55
<br /> j D 2X MIN SOUTHERN PINE WOOD #10 WOOD SCREW 1-3/8" 3/4"
<br /> G=0.55
<br /> E 16 GAUGE 0.060 MIN. STEEL 10-16 ITW TEKS FULL THREAD 1/2"
<br /> STUD 33KSI YIELD MIN. SELF—DRILLING SCREW
<br /> 1 8 ALUM. 6063—T5 MIN. OR 10 GRADE 5 SELF—TAPPING
<br /> F 1 8" STEEL 36 KSI MIN. DRILLING SCREW FULL THREAD 1/2"
<br /> NOTES:
<br /> 1.This installation has been evaluated for use in locations adhering to the Florida Building Code outside the HVHZ,and where pressure requirements as determined by ASCE 7 Minimum Design Loads for
<br /> Buildings an I Other Structures do not exceed the design pressure ratings herein.
<br /> 2.For anchorag 2 r iquirements in various substrates see Table 1. A minimum distance of 3"shall be maintained between any two installation fasteners.
<br /> 3.All interior ar d exterior perimeter surfaces of the window must be caulked.
<br /> 4.Anchor type,size,spacing,embedment,and edge distance shall be as specified in these drawings.
<br /> S.Anchor embedrr ent to substrate shall be beyond wall dressing or stucco.For masonry openings with wood bucks less than 1-1/2"thick,embedment shall be beyond wood bucks,If used,and into
<br /> masonry substi ate.Wood bucks with masonry are optional.
<br /> 6.Wood or mas 3ni y openings,bucks,and buck fasteners,by others,shall be properly designed and installed to transferwind loads to the structure.
<br /> 7.The responsibili y for selection of Simonton products to meet any applicable local laws,building codes,ordinances,or other safety requirements rests solelywith the architect,building owner,or
<br /> contractor.
<br /> 8.Shims are re ut ed where gaps of greater than 1/16"exist between opening and frame.Max.shim stack is 1/4". Shims shall be load-bearing and capable of transferring loads to the substrate.
<br /> 9.When used in areas requiring impact protection,this product REQUIRES the use of approved impact resistant shutters or other external protection.
<br /> 10.Sealing and Bashing by others should be applied using the ASTM E 2112 methodology appropriate for the opening into which the product is being installed.Overall water penetration resistance of the
<br /> installed produ t is not addressed in this drawing and is the responsibility of others.
<br /> 11.Glazing shall comply with ASTM E 1300-04.
<br /> 12.All fasteners penetrating Into pressure treated wood shall be capable of preventing corrosion due to reaction with pressure treatment chemicals. Any dissimilar materials that come Into contact shall
<br /> be protecte tc prevent reactions in accordance with code requirements.
<br /> 13.A wind load u ation factor Cd=1.6 was used for the analysis of wood screws only.
<br /> 14.Products shal bR constructed as specified in test reports D2310.01-501-47,C3526.01-501-47 and C3522.01-501-47 by Architectural Testing,Inc-Springdale,PA and C5630.01-109-47 and
<br /> C2276.01-1(9- 7 by Architectural Testing,Inc-York,PA.
<br /> 15.Use 100%pu a ilicone caulk compliant with AAMA 800 Section 1 -Sealant Specifications for use with Architectural Fenestration Products. Make sure surfaces are completely free from all old caulk,
<br /> damaged wc o ,wood fibers,grease,oil dirt,rust,mold or similar contaminants.Vacuum and clean opening surfaces completely.A fully primed surface is recommended,but not required.Cleaning
<br /> of all surfac s hould be done the same day of which the silicone caulk is to applied.For more details visit Simonton.com.
<br /> I S.Caulk applica io :recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F. Insure all-contact surfaces are clean and dry including the new
<br /> window(s).. Js a backer rod on all joints>3/4"deep and/or wider than 1/4". Finished caulk joint should be a minimum of 3/8"deep and make full contact with both the newwindow and structural
<br /> opening sur ac as.Silicone caulk should be forced into joint or compressed to assure full contact on both surfaces and to expel any air pockets.
<br /> MATERIAL' �1 SIZE:ORA ING NO.: REV.
<br /> RMS FINISH: SIMONTON'This B IN0434 6
<br /> DISCLOSURE thl,d ENT mess Olonal Talep.dn / DRAWN BY: DATE:
<br /> .nddecemenl is the property of ttm Ton Wlndews,.p I Wins 011 pmpd,Wry Unless Olh¢rwl5e 500U6ed I N 5
<br /> LMN 03108/1)
<br /> andhe er rights to o diu.n t matter.This documentis pm"Ided to the recipient ALLOY 6 TEMPER: 1 eomb.ne MIV 264 CHECKED BV• DATE:
<br /> on L n,,pressed w)—tio Neill is not la,,dkcl"sed,reproduced rgoode or PenuShnm,�1'V 2fi415
<br /> part,na oths,h,Sir n ton ith Wind the design,mowfodure T is asotgonds les WpG T: VOLUME: Declmal8 Angl¢6
<br /> anyonealharlhen$ImpnWnWindowswiihoulgsmnsenlThisreslricGondoes SCALE; SHEET: APPRVDBV: DATE:
<br /> not UM1 the iedpl,nl's rights to uilGze InlormalWn—Wined In his decumenl .%=.03 FIT 7of2
<br /> which is properlyobaIned lrom onolher source, SURFACE AREA: PER ETER: SERIES:
<br /> .%%Y.01 0'30 min.
<br /> FINISH TREATMENT: .xxx 1.005 43-40143-45 DOUBLE HUNG
<br /> TITLE
<br /> FILE FU15167.13 1X BUCK INSTALLATION