Laserfiche WebLink
tnxTower .lob Pasco County (VS) (BU 826548) Page 2 of 31 <br /> Tower Engineering Project Date <br /> Professionals TEP No. 48167.314456 10:28:19 10/21/19 <br /> 326 Tryon Road <br /> Raleigh,NC27603 Client Designed b <br /> Phone:(919)661-6351 Crown Castle g y <br /> FAX.(919)661-6350 CdCrOOIC <br /> Wind 180 <br /> Leg A <br /> Wind 90 <br /> Leg C Z Leg B <br /> Face C <br /> Wind Normal <br /> Triangular Tower <br /> Tower Section Geometry <br /> Tower Tower Assembly Description Section Number Section <br /> Section Elevation Database Width of Length <br /> Sections <br /> h h h <br /> Tl 190.00-180.00 8.00 1 10.00 <br /> 72 180.00-160.00 8.00 1 20.00 <br /> T3 160.00-140.00 8.00 1 20.00 <br /> T4 140.00-120.00 9.67 1 20.00 <br /> T5 120.00-113.33 11.33 1 6.67 <br /> T6 113.33-106.67 11.89 1 6.67 <br /> T7 106.67-100.00 12.44 1 6.67 <br /> T8 100.00-80.00 13.00 1 20.00 <br /> T9 80.00-70.00 14.67 1 10.00 <br /> T10 70.00-60.00 15.50 1 10.00 <br /> T11 60.00-40.00 16.33 1 20.00 <br /> T12 40.00-30.00 18.00 1 10.00 <br /> T13 30.00-20.00 18.83 1 10.00 <br /> T14 20.00-0.00 19.67 1 20.00 <br /> Tower Section Geometry cont'd <br /> Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt <br /> Section Elevation Spacing Type K Brace Horizontals Offset Offset <br /> End <br /> ft R Panels in in <br /> T1 190.00-180.00 5.00 X Brace No No 0.0000 0.0000 <br />