Laserfiche WebLink
I <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING, CONSTRUCTION <br /> Florida Department of Business and Professional Regulation -.Residential Performance Method <br /> ProjectName: HIGHGATE Builder-Name: Mario's Air Cond'tioning and Heating Inc. <br /> Street: 6426 Bradford Woods Drive Permit Office: .�,'a j s ze� y;�irffj <br /> City,State,Zip: Zephryhills,FL,33542 Permit Number: ZZ , <br /> Owner: HIGHGATE Jurisdiction:_ 01(poD <br /> Design Location: FL,Tampa County- PASCO(Florida Climate Zone 2) <br /> :1. New construction or existing New(From Plans) 9. Wall Types.(1864.5 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block.-Int Insul,Exterior R=4.1 1525.50 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 339.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1779.0 sgft'.) Insulation Area <br /> 5. Is this-a worst case? Yes a.Under Attic(Vented) R=30.0 1779.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1850 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) .0. c.N/A R= ft2 <br /> .11.Ducts R ft2 <br /> 7.-Windows(221.1 .sgft.) Description Area a.Sup:Attic,Ret:LIVING,AH:LIVING .. . . 6 710 .. <br /> a. U-Factor: Dbl,U=0:35 173:14 ft2 <br /> SHGC: SHGC=6.29 <br /> b. U-Fa ctor: Dbl,U=0.63 48.00 ft2 12.Cooling system_s kBtu/hr Efficiency: <br /> SHGC: ... SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor:- N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.171 ft. <br /> Area Weighted Average SHGC: 0.297 14.Hot water.systems <br /> 8. Floor Types (1779.0,sqft.) Insulation Area a.Electric Cap:40gallons <br /> EF:0.920920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 .1779.00 ft2 b.Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: .0.120 -Total Proposed Modified Loads: 64.13 PASS <br /> Total Baseline Loads: 65.44 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ScTKE Sr9T. <br /> this calculation are in compliance with the Florida Energy specifications covered by this, fyo� <br /> Code. : ; calculation indicates compliance <br /> with the Florida.Energy Code: rrrrr '•% %; �;ti O <br /> PREPARED BY: i" �' �� Before construction is completed <br /> DATE: 19iQt9n1 o this building will be inspected.for <br /> compliance with Section 553.908 <br /> hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. COD 1yy61�� <br /> OWNER/AGENT: Snezana Gurcinovska BUILDING OFFICIAL: <br /> DATE: 1219119 DATE: <br /> - compliance requires certification by the air handler unit.manufacturer that the air handier enclosure qualifies as . . . . <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project:requires <br /> an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). <br /> 12/9/201,9 1:36 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 <br /> I - <br /> I <br />