Laserfiche WebLink
i <br /> - - wrightsoft" Manual S Compliance Report Date: Feb 26,2019 <br /> Entire House By: <br /> Mario's Air Conditioning and Heating Inc. <br /> 9213 Denton Ave,Hudson,FL 34667 Phone:727-843-9598 Fax:727-645-6957 Email:info@mariosac.com Web:www.mariosac.com j <br /> Project, <br /> • • <br /> For: HIGHGATE, PULTE HOMES <br /> LOT 42 BLK 02 . <br /> Cooling Equipment <br /> .Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 24217 . Btuh Entering coil DB: 75.0°F <br /> Outdoor design WB: 77.2°F Latent gain: 3353 Btuh Entering coil WB: 64.0°F <br /> Indoor design DB:. 75.07 Total gain: 27571 Btuh <br /> Indoor RH: 55% Estimated airflow: 946 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-22+CBA27UHE-030-230"++TDR <br /> Actual airflow: 946 cfm <br /> Sensible capacity: 25418 Btuh 105% of load <br /> Latent capacity: 5551 Btuh 166% of load <br /> Total capacity: 30969 Btuh 1121/o of load SHR: 82% <br /> Heating Equipment <br /> Design.Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 19500 Btuh Entering coil DB: 70.0°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-030-230-22+CBA27UHE-030-230*++TDR <br /> Actual airflow: 946 -cfm <br /> Output capacity: 26000 Btuh 133% of load Capacity balance: 35 °F <br /> Supplemental heat required: 0 Btuh Economic balance: , -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 946 cfm <br /> Output capacity: 0 - kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual_S. <br /> -> - wrilghtsoftm 2019-Dee-09 13:16:15 <br /> „�^ ,. .•, ..m..., Rig ht-Suits@ Universal 2018 18.0.32 RSU18255 Page 1 <br /> A+�► ...eDrive\Pulte Homes\LOAD CALC FILES\HIGHGATE.rup Calc=MJ8 Front Door faces:NW <br />