Laserfiche WebLink
i <br /> FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> FLOORS <br /> I <br /> # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet <br /> 8Slab-On-Grade Edge Insulation BED lift 0 137ft2 0 1 0 <br /> I <br /> 9Slab-On-Grade Edge Insulation BA2 5ft 0 50ft2 ____ 0 1 0 <br /> 10SIab-On-Grade Edge Insulation BED2 32ft b 184ft2 - ____ 0 1 0 <br /> ROOF <br /> / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch <br /> V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) <br /> 1 Gable orShed Composition shingles 1875 ft2 296 ft2 Medium N 0.01 No 0.9 No 0 18.4 <br /> ATTIC <br /> V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC <br /> 1 Full attic Vented 300 1779 ft2 N N <br /> CEILING <br /> # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type <br /> 1 Under Attic(Vented) OWNERS 30 Blown 224ft2' 0.1 Wood <br /> 2 Under Attic(Vented) O.BTH 30 Blown 120 ft2 0.1 Wood <br /> 3 Under Attic(Vented) WIC 30 Blown 56ft2; 0.1 Wood <br /> 4 Under Attic(Vented) BED4 30 Blown 121 ft2. 0.1 Wood <br /> 5 Under Attic(Vented) LAUND 30 Blown 49 ft2, 0.1 Wood <br /> 6 Under Attic(Vented) FOYER 30 Blown 75 ft2 0.1 Wood <br /> 7 Under Attic(Vented) LIVING 30 Blown 763ft2 0.1 Wood <br /> 8 Under Attic(Vented) BED 30 Blown 137ft2 0.1 Wood <br /> 9 Under Attic(Vented) BA2 30 Blown 50ft2, 0.1 Wood <br /> 10 Under Attic(Vented) BED2 30 Blown 184 ft2 0.1 Wood <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 111P Ft In Ft In Area R-V;,111e Fraction AhSnr rrarip% <br /> 1 S=>N Exterior Concrete Block-Int Insul OWNERS 4.1 16 0 9 5 150.7 ft2 0 0 0.01 0 <br /> 2 W=>E Exterior Concrete Block-Int Insul OWNERS 4.1 14 0 9 5 131.8 ftZ 0 0 0.01 0 <br /> 3 S=>N Exterior Concrete Block-Int Insul O.BTH 4.1 12 0 9 5 113.0 ft2 0 0 0.01 0 <br /> 4 S=>N Exterior Concrete Block-Int Insul BED4 4.1 11 0 9 5 103.6 ft2 0 0 0.01 0 <br /> 5 E=>W Garage Frame-Wood BED4 13 11 0 9 5 103.6 ft2 0 0.25 0.01 0 <br /> 6 E=>W Exterior Concrete Block-Int Insul FOYER 4.1 5 0 9 5 47.1 ft2 0 0 0.01 0 <br /> _ 7 S=>N Garage Frame-Wood FOYER 13 15 0 9 5 14113 ft2 0 0.25 0.01 0 <br /> 8 N=>S Exterior Concrete Block-Int Insul LIVING 4.1 31 0 9 5 2911.9 ft2 0 0 0.01 0 <br /> 9 W=>E Exterior Concrete Block-Int Insul LIVING 4.1 25 0 9 5 235.4 ft2 0 0 0.01 a <br /> 10 E=>W Garage Frame-Wood LIVING 13 10 0 9 5 942 ft2 0 0.25 0.01 0 <br /> 11 N=>S Exterior Concrete Block-Int Insul BED 4.1 11 0 9 5 103.6 ft2 0 0 0.01 0 <br /> 12 N=>S Exterior Concrete Block-Int Insul BA2 4.1 5 0 9 5 47:1 ft2 0 0 0.01 0 <br /> i <br /> 12/9/2019 1:36 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) ComIpliant Software Page 3 of 5 <br />