Laserfiche WebLink
March 26, 2019 <br /> 287.667 Ft Self Support Tower Structural Analysis CCI BU No 816298- <br /> Project Number 9800.816298,Phase 4, Order 485277, Revision 1 Page 13 <br /> Tower Input Data <br /> The main tower is a 4x free standing tower with an overall height of 287.67 ft above the ground line. <br /> The base of the tower is set at an elevation of 0.00 ft above the ground line. <br /> The face width of the tower is 10.00 ft at the top and 45.54 ft at the base. <br /> This tower is designed using the TIA-222-H standard. <br /> The following design criteria.apply: <br /> 1) Tower is located in Pasco County, Florida. <br /> 2) Tower base elevation above sea level: 82.00 ft. <br /> 3) Basic wind speed of 138 mph. - <br /> 4) Risk Category II. <br /> 5) Exposure Category C. <br /> 6) Simplified Topographic Factor Procedure for wind speed-up calculations is used. <br /> 7) Topographic Category: 1. <br /> 8) Crest Height: 0.00 ft. <br /> 9) Deflections calculated using a wind speed of 60 mph. <br /> 10) TIA-222-H Annex S. <br /> 11) Pressures are calculated at each section. <br /> 12) Tower analysis based on target reliabilities in accordance with Annex S. <br /> 13) Load Modification Factors used: Kes(Fw)= 0.95. <br /> 14) . Stress ratio used in tower member design is 1.05. j <br /> 15) Local bending stresses due to climbing loads,feed line supports, and appurtenance mounts are <br /> not considered. <br /> Options <br /> Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 1'0 X-Brace Ly:Rules <br /> Consider Moments-Horizontals Assume Legs Pinned 4 Calculate Redundant Bracing Forces <br /> Consider Moments-Diagonals 4 Assume Rigid Index Plate Ignore Redundant Members in FEA <br /> Use Moment Magnification 4 Use Clear Spans For Wind Area SR Leg Bolts Resist Compression <br /> Use Code Stress Ratios 4 Use Clear Spans For KUr All Leg Panels Have Same Allowable <br /> Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation <br /> Escalate Ice 4 Bypass Mast Stability Checks 4 Consider Feed Line Torque <br /> Always Use Max Kz 4 Use Azimuth Dish Coefficients 4 Include Angle Block Shear Check <br /> Use Special Wind Profile q Project Wind Area of Appurt. Use TIA-222L H Bracing Resist._ <br /> Exemption <br /> 4 Include Bolts-in Member Capacity Autocalc Torque Arm Areas Use TIA-2221 H Tension Splice <br /> Exemption <br /> Leg Bolts Are At Top Of Section Add IBC.6D+W Combination _ Poles <br /> 4 Secondary Horizontal Braces Leg 4 Sort Capacity Reports By Component Include Shear-Torsion Interaction <br /> 4 Use Diamond Inner Bracing(4 Sided) 4 Triangulate Diamond Inner Bracing Always Use Sub--Critical Flow <br /> SR Members.Have Cut Ends Treat Feed Line bundles As Cylinder Use Top Mo l nted Sockets <br /> SR Members Are Concentric Ignore KUry For 60 Deg.Angle Legs Pole Without Linear Attachments <br /> Pole With Shroud Or No <br /> Appurtenances <br /> Outside and Inside Comer Radii Are <br /> Known <br /> I <br /> tnxTower Report-version 8.0.5.0 <br /> i <br /> I <br /> - I <br />