Laserfiche WebLink
INSTALLATION WITH FLANGE FRAME <br /> S ST EXTERIOR <br /> ISU RA SU <br /> ix o <br /> SHIM <br /> WOOD <br /> SHIM \ <br /> I <br /> EDGE <br /> DISTANCE <br /> NO <br /> ANCHORS NO SHIM <br /> REQUIRED ANCHORS EMBEDMENT—�-------I <br /> EXTERIOR REQUIRED EXTERIOR <br /> FLANGE FRAME, <br /> JAMB INSTALLATION •� <br /> (DIRECTLY TO SUBSTRATE) 1 <br /> FLANGE FRAME, <br /> HEAD INSTALLATION FLANGE FRAME, <br /> (DIRECTLY TO SUBSTRATE) HEAD INSTALLATION <br /> (USING 1X BUCKSTRIP) <br /> SU T7; <br /> / EXTERIOR <br /> E <br /> EXTERIOR <br /> EXTERIOR <br /> EDGE <br /> NO NO DISTANCE <br /> ANCHORS ANCHORS <br /> REQUIRED REQUIRED 1X SHIM <br /> EMBEDMENT ---I' 'NDDD Y/' <br /> 0 FLANGE FRAME, .��,.`� _ <br /> JAMB INSTALLATION '1'•'•4 r <br /> SHIM I SHIM (USING 1X BUCKSTRIP) <br /> ly <br /> ix <br /> WOOD <br /> a..n cr or.: wnm� nEercoauriaiAL#Yc retavram <br /> FLANGE FRAME, BST TE J.RDSOWSKI 01118/13 ALUMINUM 6063-T6N6"Eraur ocror <br /> r,occm�,uo cm+esem aracmmu <br /> SILL INSTALLATION A�rROFF.>FrAWWPCRV"p`TY°° <br /> (DIRECTLY TO SUBSTRATE) FLANGE FRAME, �` � R !le+H j <br /> SILL INSTALLATION °�� "� <br /> INSTALLATION NOTES: (USING 1X BUCKSTRIP) ® Dm.* 1 <br /> 1)SEE SHEET 1 FOR ANCHORAGE,SUBSTRATE AND SPACING REQUIREMENTS. 1070 TECHNOLOGY DRIVE <br /> 2)GLASS SHOWN AS EXAMPLE.MAY VARY BY SERIES AND DESIGN PRESSURE REQUIREMENTS. NOKOMIS,FL 34275 <br /> 3)FOR SMOOTH SASH OPERATION,THE ANCHORS MUST BE FLATHEADS. FL CERT.OFAUfH.:29298 SINGLE HUNG INST.,HD MEETING RAIL <br /> 4)MAX.SHIM THICKNESS TO BE 1/4% A.Lynn Miller,P.E. S.�� �` me.e D..4vw ^ . <br /> 5)FLANGE MAY BE REMOVED TO CREATE EQUAL-LEG FRAME-USE FLANGE FRAME INSTALLATION. P.E.#58705 SH-200 NTS 2 of 3 1032412JR <br /> I <br /> 1 <br />