Laserfiche WebLink
Q <br /> j <br /> • <br /> ED <br /> I <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.cornply with R401.3 of the F.B.C. <br /> 3. Compaction test required'if 24" or more of fill dirt is brought in at-any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5; Driveways require.a R.O.W. use permit_. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be in et. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> & All A.D.A.-requirements shall be met: . <br /> 9: No electric,plumbing, mechanical, or framing shall be covered without an inspection.and <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 1.1. Appliances shall not be installed in a location.where subject.to mechanical damage unless <br /> protected by approved barriers. M3014 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308.:1 <br /> 14. Return air in all bedrooms. F.B.C' .. M1620.4 <br /> 1.5. Smoke detectors are to be- installed in accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance:with R308A.of the .RC. <br /> 17. All means of egress are to;be in accordance with R311 of the F.B.C.; <br /> 18. "Green gypsum,board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.' They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit;to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 201-6 N.E.C. Codes will be enforced: <br />