Laserfiche WebLink
23. Tamper-Resistant.Receptacles in accordanee with 406.11 of the 2016iN.E.0 <br /> 24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10 <br /> feet around the structure: . <br /> 25. R403.5.3Hot water,pipe insulation. <br /> insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following::. <br /> Piping:V, inch (19.1 mm) and larger,in.:nominal diameter: <br /> Piping.serving more than one dwelling unit: <br /> Piping located_outside the conditioned space. <br /> Piping from the water heater to a distribution manifold:. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25:Blower door test shall be provided.before C.O: . <br /> 26.A copy of the energy tack shall be-with permit at all times <br /> 27. Copy of final insulation reyort shall be provided ivith permit before final <br /> 28.No.fence,pool or screen enclosure :is issued with ahis.permit <br /> F.F.E.-.Finished Floor Elevation <br /> RB.C--Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way. <br /> A.D.A.-.Americans with Disabilities Act N.E.C.-.National Electric-!Code (2016) <br /> i <br /> i <br /> i <br /> i <br /> i <br /> i <br /> i <br />