Laserfiche WebLink
i <br /> 23. Tamper-Resistant Receptacles in accordance with 406:11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots_ shall be sodded before final at least 10 <br /> feet around-the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation-forhot:water'pipe with a minimum thermal resistance_(R-value) of R-3 shall be applied to the <br /> - <br /> following: <br /> Piping 31;inch (19.1 mm)and larger in.:nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to.a distribution manifold. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower.door test shall be provided Before C.Q: <br /> 26.A cony of the energy:cacls shall be.with permit at all.times <br /> 27 Cony offinal insulation report shall be provided with permit before real <br /> 28:No fence,pool or'screen enclosure :is issued with:thispermit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way; <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code (2016)- <br /> i <br />