Laserfiche WebLink
H) <br /> 4 <br /> t <br /> k i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E:,shall be a minimum of 8"above the road elevation and an'engineered site plan. <br /> .2: Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill,dirt is brought in at any one place. <br /> 4: Tie in survey ,required before pouring concrete. <br /> 5; Driveways require a R.O.W. use permit. All 4 sides of driveway thM the sidewalk shall have <br /> expansion material. <br /> 6- All setbacks shall be met. <br /> . <br /> T. All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A."requirements shall be met: <br /> 9; No electric,plumbing;mechanical, or framing shall.be covered without an inspection.and <br /> approval first. <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. . (Fire Separation).: <br /> 11. Appliances shall.not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B:C. <br /> 13. Foundation supports for A/C units:shall.be raised_ at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M16N.A <br /> 15. Smoke detectors are to be installed in accordance with R313J of the F.B.C. <br /> 16.All glazing requirements are to be.in accordance with R308A of the RB.C: <br /> 17. All means of egress are.to be in accordance with R311 of the F.B.C. <br /> 18. "Green.gypsum board"shall not be used as a backer in showers or tubs. R702A.2 F.B.C. . <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be-installed in accordance.with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />